Functions
SF4C Safety light curtain
72
3.6 Auxiliary Output (Non-Safety Output)
The SF4C is equipped with an auxiliary output for non-safety-related purposes. The auxiliary
output is incorporated with the emitter.
Normal mode
Control output (OSSD 1, OSSD 2) status
Auxiliary output
setting
Test input
activated
Beam received
Beam blocked
Lockout
Negative logic of OSSD
(factory setting)
ON OFF ON
ON
NOTE
You can switch the output operation for auxiliary output with the handy controller.
Reception status
Control output
(OSSD 1, OSSD 2)
Auxiliary output
Negative logic of
(OSSD 1
Beam
received
Beam
blocked
ON
OFF
ON
OFF
90ms or less
7ms or
less
10ms or less
10ms or less
Time diagram
!
DANGER!
Do not use the auxiliary output to stop the machine as this could
result in serious injury or death.
Rugghölzli 2
CH - 5453 Busslingen
Tel. +41 (0)56 222 38 18
Fax +41 (0)56 222 10 12
mailbox@sentronic.com
www.sentronic.com
Produkte, Support und Service
SENTRONIC
AG