34
© Panasonic Industrial Devices SUNX Co., Ltd. 2016
English
3. Functional Description
<Common to emitter and receiver>
Description
Function
Large multi-purpose
indicator (Red / Green)
Lights up in red when the large multi-
purpose indicator input is valid.
Lights up in green when the large multi-
purpose indicator input is valid.
Turns OFF when the input is invalid.
Incident light intensity
indicator
(Green / Orange)
Lights up in green when stable light is received.
Lights up in orange when unstable light is received.
Turns OFF when light is blocked.
Beam-axis align-
ment indicator
(Red / Green)
A
Lights up in red when device top receives light.
Blinks in red when device top end receives light.
Lights up in green when control output (OSSD 1 / 2) is ON.
B Lights up in red when device upper middle receives light.
Lights up in green when control output (OSSD 1 / 2) is ON.
C Lights up in red when device lower middle receives light.
Lights up in green when control output (OSSD 1 / 2) is ON.
D
Lights up in red when device bottom receives light.
Blinks in red when device bottom end receives light.
Lights up in green when control output (OSSD 1 / 2) is ON.
Digital error indicator
(Red) (Note)
Error contents are indicated when device
is lockout.
Fault indicator (Yellow) Lights up or blinks when fault occurs in the device.
PNP indicator (Orange) Lights up when PNP output is set.
NPN indicator (Orange) Lights up when NPN output is set.
<Emitter>
Description
Function
Operation indicator
(Red / Green)
Lights up when device operation is as follows.
[Sequential operation to control output (OSSD 1 / 2).]
Lights up in red when control output (OSSD 1 / 2) is OFF.
Lights up in green when control output (OSSD 1 / 2) is ON.
Test input indicator
(Orange)
Lights up when test input is valid.
Turns OFF when test input is invalid.
Safety input 1 indicator
(Orange)
Lights up when safety input 1 is valid.
Turns OFF when safety input 1 is invalid.
Safety input 2 indicator
(Orange)
Lights up when the safety input 2 is valid.
Turns OFF when the safety input 2 is invalid.
<Receiver>
Description
Function
OSSD indicator
(Red / Green)
Lights up in red when control output (OSSD 1 / 2) is OFF.
Lights up in green when control output (OSSD 1 / 2) is ON.
Function setting indi-
cator (Orange)
Blinks when the handy controller is connected.
Lights up when blanking function is valid.
Interlock indicator
(Yellow)
Lights up when interlock is valid.
Turns OFF when interlock is invalid.
Muting input 1 indicator
(Orange)
Lights up when muting input 1 is valid.
Turns OFF when muting input 1 is invalid.
Muting input 2 indicator
(Orange)
Lights up when muting input 2 is valid.
Turns OFF when muting input 2 is invalid.
Note: In case of SF4C-F□, the position of digital indicator (red) is different as right
figure.
Also, digital indicator (red) is not incorporated in
SF4C-F15
□
Indicator section of emitter
Fault indicator
PNP indicator
NPN indicator
Test input
indicator
Safety input 1
indicator
Safety input 2
indicator
Incident light
intensity indicator
Beam-axis align-
ment indicator A
Operation indicator
Beam-axis align-
ment indicator B
Beam-axis align-
ment indicator C
Beam-axis align-
ment indicator D
Digital
error
indicator
(Note)
Fault indicator
PNP indicator
NPN indicator
Function set-
ting indicator
Interlock
indicator
Muting input
1 indicator
Muting input
2 indicator
Incident light
intensity indicator
Beam-axis align-
ment indicator A
OSSD indicator
Beam-axis align-
ment indicator B
Beam-axis align-
ment indicator C
Beam-axis align-
ment indicator D
Digital
error
indicator
(Note)
Indicator section of receiver
Beam-axis side
Front
Back
Large multi -purpose indicator
Location of beam-axis alignment indicator
<
SF4C-H
□
>
<
SF4C-F
□
>
Digital error indicator
Summary of Contents for SF4C Series
Page 7: ...7 Panasonic Industrial Devices SUNX Co Ltd 2016 Japanese 4 2 S SF4C H 0V PNP 1 2 3 4...
Page 19: ...19 Panasonic Industrial Devices SUNX Co Ltd 2016 Japanese 6 6 FSD FSD...
Page 22: ...22 Panasonic Industrial Devices SUNX Co Ltd 2016 Japanese 0V V 0V V 1 2 1 2 2...
Page 25: ...25 Panasonic Industrial Devices SUNX Co Ltd 2016 Japanese OSSD 2...
Page 63: ...63 Panasonic Industrial Devices SUNX Co Ltd 2016 Chinese 4 2 S SF4C H 0V PNP 1 2 3 4...
Page 75: ...75 Panasonic Industrial Devices SUNX Co Ltd 2016 Chinese 6 6 1 2 3 4 5 6 FSD 7 FSD...
Page 78: ...78 Panasonic Industrial Devices SUNX Co Ltd 2016 Chinese 0V V 0V V 1 2 1 2 2 5 3 4 2...
Page 81: ...81 Panasonic Industrial Devices SUNX Co Ltd 2016 Chinese SF4C F15 OSSD 2...
Page 87: ...87 Panasonic Industrial Devices SUNX Co Ltd 2016 Korean 1 1 2 OSHA...
Page 91: ...91 Panasonic Industrial Devices SUNX Co Ltd 2016 Korean 4 2 S mark 0V PNP 1 2 3 4...
Page 103: ...103 Panasonic Industrial Devices SUNX Co Ltd 2016 Korean 6 6 1 2 3 4 5 6 FSD 7 FSD...
Page 106: ...106 Panasonic Industrial Devices SUNX Co Ltd 2016 Korean 0V V 0V V 1 2 1 2 2...
Page 109: ...109 Panasonic Industrial Devices SUNX Co Ltd 2016 Korean OSSD 2...
Page 115: ......
Page 116: ......