Adjustment
© Panasonic Industrial Devices SUNX Co., Ltd. 2020
75
2-6 Adjustment
2-6-1 Beam Adjustment
Step 1 Supply power to the device.
Step 2 When the device starts, “ ” (when PNP output is set) or “ ” (when NPN output is set)
lights yellow on the digital indicator.
Step 3 Make sure that the digital indicators on the emitter and receiver are OFF.
If a yellow number blinks or lights in the digital indicator, refer to
Normal state
Error state
Digital indicator
Step 4 Check the upper application indicator and lower application indicator on the emitter, the
operation indicator, the upper application indicator and lower application indicator on the
receiver, and the OSSD indicator.
If the upper application indicator and lower application indicator light red or are OFF, or
the operation indicator and OSSD indicator light red, the beam axes are out of alignment.
All beams blocked state
Upper application
indicator
Lower application
indicator
Emitter: Operation indicator
Receiver: OSSD indicator
Emitter
Receiver
<Horizontal misalignment>
Normal position
<Vertical misalignment>
Normal position