Functions
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
106
<Timing chart (Error 2)>
ON
ON
OFF
OFF
300ms or less
50ms or less
(Note 2)
External device
monitor input
Control output
(OSSD 1 / 2)
Light received
Light blocked
Light received
state
Lockout state
Notes: 1) The response time depends on the number of beam channels.
Response time (OFF response)
Main sensor
Sub sensor
Number of units in
series connection
1 unit
1 unit 2 units 3 units 4 units 0 unit 0 unit 1 unit 1 unit 2 units 2 units 3 units
Number of units in
parallel connection
0 unit 0 unit 0 unit 0 unit 1 unit 2 units 1 unit 2 units 1 unit 2 units 1 unit
Number of beam channels
4 to 48
6ms
10ms 10ms 12ms 12ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms
49 to 96
8ms
10ms 10ms 12ms 12ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms
97 to 127
10ms
12ms 12ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms
128 to 144
−
12ms 12ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms 14ms
145 to 192
−
14ms 14ms 16ms 16ms 14ms 14ms
−
−
−
−
−
193 to 256
−
16ms 16ms 18ms 18ms
−
−
−
−
−
−
−
2) Using the communication module
SF4D-TM1
(option), you can change the allowed response time with-
in the range 100 to 600ms.
Summary of Contents for SF4D-x-01 Series
Page 2: ... Panasonic Industrial Devices SUNX Co Ltd 2017 2 MEMO ...
Page 126: ...Functions Panasonic Industrial Devices SUNX Co Ltd 2017 126 MEMO ...
Page 130: ...Maintenance Panasonic Industrial Devices SUNX Co Ltd 2017 130 MEMO ...
Page 140: ...Troubleshooting Panasonic Industrial Devices SUNX Co Ltd 2017 140 MEMO ...
Page 174: ... Panasonic Industrial Devices SUNX Co Ltd 2017 174 MEMO ...