3-3 Lockout Release Function (Common for all cables)
This function releases the device from the lockout state and returns it to normal operation.
When in the lockout state, the device is returned to normal operation by removing the cause of
the lockout, performing lockout release: [open the output polarity setting / lockout release input
wire (pale blue) that was short-circuited, and then short-circuit within approx. 150ms to 4 sec.].
<Timing chart>
Open
Normal
Shorted
Lockout
Output polarity
setting / lockout
release
Operation
150ms to 4 sec.
2 sec. or less
*Switch S1
● Output polarity setting / Lockout release input
0 to +2.5V (source current 5mA or less):
Short circuit
<Using PNP output>
(Brown)
(Pale blue)
*S1
(Blue)
*Switch S2
● Output polarity setting / Lockout release input
Vs to Vs − 2.5V (sink current 5mA or less):
Short circuit (Note)
Note: Vs is the supply voltage.
(Brown)
(Pale blue)
(Blue)
<Using NPN output>
*S2