SAFETY PRECAUTIONS

In this operating instruction sheet, safety precautions are categorized to  Caution:

Caution notices are used where inattention might cause personal injury or damage to equipment.

1

Type

SG-B2-K□-L5

Safety switch

the manual rear 

unlocking button

Mounting screw

 (M3 sems screw)

Panel

Rod

CAUTION

4

Precautions for Operation

CAUTION

5

Adjustments

4.6 mm

SG-K22

SG-K21

3.3 mm

 Safety

Switch

Center

1.0 mm

1.0 mm

Recommended Screw  Tightening Torque

CAUTION

CAUTION

SG-K22

SG-K22A

  Mounting centers:12 mm

 

Mounting centers:20 mm

SG-K24

R1

230 mm
230 mm
310 mm

70 mm

(Horizontal Swing)

R2

260 mm

260 mm

70 mm

(Vertical Swing)

R3

170 mm
120 mm
170 mm

50 mm

(Horizontal Swing)

R4

190 mm

140 mm

50 mm

(Vertical Swing)

Minimum Radius

Actuator

Stop

Actuator

Cover

Safety Switch

Door Stop

Safety Switch

Actuator

Stop

SG-K21

Actuator

SG-K22

Actuator

Door Stop

(Actuator deviation) 

+ 

(Door movement)

 3.3mm

 4.6mm

 4.6mm

SG-K21

SG-K22

SG-K21A

SG-K22A

SG-K24

Contact Configuration and Operation

6

Contact Operation and Wiring

Operation Cycle

Door States

Main Circuit

Monitor Circuit

Monitor Circuit
Monitor Circuit

Monitor Circuit

Key Position

/Rear Unlock Button

11-42

21-52

11-12

21-22
23-24
41-42

51-52
53-54

Closed
Closed

Closed

Open

Closed

Open

Lock Position

/

Returned status

Door is locked.

The machine can

be operated.

Open
Open

Open

Closed

Open

Closed

Unlock Position

/

Returned status

The machine can

not be operated.

Closed

Open

Closed

Open

Open

Closed

Unlock Position

/

Returned status

Door is unlocked.

The machine can

not be operated.

Closed

Open

Closed

Open

Open

Closed

Lock Position

/When operating

the Button

Door is unlocked.

The machine can

not be operated.

Insulator Color

White

Black

Brown

Blue

Brown / White

Orange

Insulator Color

Blue / White

Orange / White

Pink

Pink / White

Gray

Gray / White

No.

1
2
3
4
5
6

No.

7
8
9

10
11
12

Colored Insulator

Jacket

2 1

10

12

11

Circuit No.

11

12

21, 23

22, 24

51, 53

52, 54

41

42

Insulator Color

Blue

Blue / White

Orange

Orange / White

Brown

Brown / White

Pink

Pink / White

Lock Release

the Rear Unlock Button

13.4

2

0

2

2

M

4

106

φ

30

27

7.

7

21.

5

33

5

6

±

1

20

40

11

±

1

R2.

2

73.2

36.2

20

28

106

145.7

(6.3)

20 3

5

1

1

6.2

5.2

30

R2.

2

73.2

1

1

35

20

(6.3)

145.7

106

36.2

28 20

26.4

6.2

5.2

30

53.

7

76.

7

40

20

11

±

1

5

33

When Shipped

Alternative Mounting Directions

(Examples of Mounting on Sliding Doors)

(Examples of Mounting on Hinged Doors)

Door Stop

Door

SG-K21

Actuator

Latch

SG-B2

Safety Switch

SG-K21S

Slide Actuator

SG-K22

Actuator

Door

SG-B2

Safety Switch

3

Mounting Examples

Actuator

Locked

When the 

SG-B2-K□

head is removed

Monitor Circuit:

UNLOCK

Monitor Circuit:

Contact Closed

Contact Open

Actuator

Unlocked

LOCK

BN

PK

BN/WH

PK/WH

51

42

52

41

Conduit

30 mm minimum radius

CAUTION

8

Precaution for Disposal

Dispose of the 

SG-B2

 safety switch as an industrial waste.

Slot plug

            4-M4

(

φ

4.3 or M4 tapped)

Main body mounting hole layout

Dimensions

SG-K22

Actuator

106

20 to 22

42.2 

to (45.5)

41 to

  (44.3)

40.3   to (44.9)

41.5

   to (46.1)

29.6

12.6

±

1

7.6

±

1

20

13.4

Manual rear unlocking button

0.8

2

R2.1

3.6

1

20

°

29

18.5

3

7

15

49

38

26

23

φ

18

hole for the

manual rear

unlocking button(reference)

Joint

(horizontal adjustment) *8

(vertical adjustment) *8

( M4 holes )

Base

Actuator stop *7

(supplied with 

actuator)

 

Angle adjusting screw

Type

SG-B2-□-L5

Type

SG-K24

Base

Angle adjusting screw

(M3 hexagon socket set screw)

38

Type

SG-K21A

Type

SG-K22A

Actuator stop *7

(supplied

  with actuator)

 

  

Manual rear 

unlocking button

            4-M4

(

φ

4.3 or M4 tapped)

Actuator mounting hole layout

(M3 hexagon socket set screw)

Joint

7

Dimensions and Mounting  (mm)

20

°

SG-K21

 Actuator

Actuator stop *7

(supplied with actuator)

SG-K21

Actuator

16

1.8

38

Key

Warning notices are used to emphasize that improper operation may cause severe personal

injury or death.

A

B

(20

)

12

2-

Ø4.3

2-Ø

10

2-Ø

9

when installed 

on the door(5)

when installed 

on the door(39.7)

when installed 

on the door(11.2)

0.8

2

0.8

8.5

15.8

15

30

Actuator stop *7

(supplied with actuator)

Actuator stop *7

(supplied with actuator)

Rubber Cushions

Rubber Cushions

Washer(supplied with actuator)

Washer(supplied with actuator)

B

the door(5)

when installed on

2-Ø 9

2-Ø10

0.8

(20)

0.8

12

2

2- Ø4.3

15

15.3

43.8

7.3

30

(horizontal adjustment)

(vertical adjustment)

Joint

Thank you very much for purchasing Panasonic products. Please read this Instruction 

Manual carefully and thoroughly for the correct and optimum use of this product. Kindly 

keep this manual in a convenient place for quick reference.

INSTRUCTION MANUAL

Safty Door Switch with Key

SG-B2

 Series

MJE-SGB2 No.0054-17V

Model No.

Key removal 

position

Cable length

SG-B2-K2AC-5

LOCK and UNLOCK

SG-B2-K2BC-5

5m

SG-B2-K2BD-5

SG-B2-K2AD-L5

SG-B2-K2CD-5

SG-B2-K2BD-L5

SG-B2-K2CD-L5

SG-B2-K2CC-5

Door monitor 

contacts

2NC

2NC

1NO + 1NC

2NC

2NC

1NO + 1NC

Lock monitor 

contacts

Push button

Without rear 

manual unlock

Rear unlock

UNLOCK

LOCK and UNLOCK
UNLOCK

LOCK

LOCK

UNLOCK
LOCK

LOCK and UNLOCK

SG-B2-K2AD-5

2

Specifications and Ratings

Applicable Standards

Applicable Directives

Thermal Current <Ith>

Contact Ratings

(Reference Values)

< Ue, Ie >

Class of Protection

Operating Frequency
Operating Speed

Mechanical durability

Actuator Tensile Strength

when Locked
Direct Opening Travel

Direct Opening Force
Contact Resistance
Degree of Protection

Short-circuit Protective Device

IEC60204-1/EN60204-1

2.5A

AC Resistive load (AC12)

Inductive load (AC15)

DC Resistive load (DC12)

Inductive load (DC13)

Class

Ⅱ 

(IEC61140) *3 

900 operations/hour
0.05 to 1.0 m/s

1,000,000 operations min. (GS-ET-19)

the Rear Unlock Button: 3000 operations min. (Type 

SG-B2-□-L5

)

1,400N min. (GS-ET-19)*4

(500N min. : 

SG-K24

 actuator)

11 mm min. (actuator: 

SG-K21

)

12 mm min. (for other actuators)
80N min.

500 m

Ω

max. (initial value, 3m cable)

 

IP65 (IEC60529)

Use 250V / 10A fast acting type fuse

250V

1.5A

0.75A
0.55A
0.27A

Standards for Use

Key

ISO14119, EN1088 

IEC60947-5-1, EN60947-5-1 

GS-ET-19, UL508, CSA C22.2 No.14

Low Voltage Directive (2014/35/EU)

Machinery Directive (2006/42/EC)

Operating Condition

-25 to +70

 (no freezing)

Electrical Durability

100,000 operations min. (AC-12 250V

1A)

1,000,000 operations min. (AC/DC 24V 100mA)

(900 operations / hour)

Operating Temperature

45 to 85

RH (no condensation)

Operating Humidity

-40 to +80

 (no freezing)

Storage Temperature

3 (Inside2)

Pollution Degree

2000m maximum

Altitude

2.5kV

Impulse withstand voltage (Uimp)

250V

*2

Rated Insulation voltage (Ui)

Mechanical Durability
Key Operating Durability
Key Tensile Strength
Direct Opening Force

Direct Opening Degree

Operating Specifications

2 Positions
100,000 operations min.
10,000 operations min.
1.0N

m min.

0.6N

m min.

60

°

 min.

B

10d

2,000,000 (EN ISO 13849-1 Annex C Table C.1)

Shock Resistance

Operating extremes: 100 m/s , Damage limits: 1000 m/s

Vibration Resistance

Operating extremes: 10 to 55 H, amplitude 0.35 mm minimum

Damage limits: 30 Hz, amplitude 1.5 mm minimum

2

2

125V

2.5A
1.5A
1.1A

0.55A

30V

-
-

2.5A
2.3A

-25℃

 < Operating temperature < 60

℃: 2.5A

60℃

 < Operating temperature < 65

℃: 1.5A

65℃

 < Operating temperature < 70

℃: 1.0A

Ratings approved by safety agencies

(1)TÜV rating

(2)UL , c-UL rating

AC-15 250V/0.75A

DC-13 125V/0.22A

DC-13 30V/2.3A

AC 125V/1.5A Pilot Duty

DC 30V/2.3A Pilot Duty  

*2: Ratings approved by UL,c-UL

125V

*3: Basic insulation of 2.5kV impulse withstand voltage is ensured between different contact 

circuits and between contact circuits and LED or solenoid in the enclosure. When both 

SELV (safety extra low voltage) or PELV (protective extra low voltage) circuits and other 

circuits (such as 230V AC circuits) are used for the solenoid power and contact circuits at 

the same time, the SELV or PELV requirements are not met any more.

*4: The actuator locking strength is rated at 1400N of static load. Do not apply a load higher 

than the rated value. When a higher load is expected to work on the actuator, provide an 

additional system consisting of another safety switch without lock or a sensor to detect 

door opening and stop the machine.

• Install the interlock switch on the immovable machine or guard, and install the actuator on the   

movable door. Do not install both interlock switch and actuator on the movable door, otherwise 

failure will occur.

• See the figures below.

The SG-B2 Head

• Changing the Mounting Directions of the 

SG-B2

 Head.

The head of the 

SG-B2

 can be 

mounted in four directions by removing 

the four screws from the corners of the 

SG-B2

 head.  

• 

Head Removal Detection Function

(Type 

SG-B2-K□

)

When the key is operated, the operation of the monitor circuit (41-42) and monitor circuits (51-52) 

are the same. However, when the head is removed, disparity is detected (41-42 : OFF, 51-52: ON). 

The disparity of the contacts detects the removal of the head.

(Type 

SG-B2-K□-L5

)

Installing the manual rear unlocking button

• 

After installing the interlock switch on the 

panel, put the manual rear unlocking 

button (supplied ) on the rod on the back 

of the interloc k switch, and fasten using 

the mounting screw. When installin g on 

the aluminum frame of the thickness of 

6mm or more, use the rear unlocking 

button for frame kit (

MS-SG-23

 / 

MS-SG-22

) sold separately.

For Mounting

• 

Do not apply an excessive shock to the safety switch when opening or closing the door.

A shock to the safety switch exceeding 1,000 m/s

2

 may cause failure.

• 

Regardless of door types, do not use the safety switch as a door lock. Install a sepatate 

lock as shown in 3.

• 

Do not open the lid of the switch. Loosening the screws may cause damage to the switch.

• 

Entry of foreign objects in the actuator entry slot may affect the mechanism of the switch 

and cause a breakdown. If the operating atmosphere is contaminated, use a protective 

cover to prevent the entry of foreign objects into the switch through the actuator entry 

slots.

• 

Do not fasten and loosen the conduit at the bottom of the safety 

switch.

• 

When wiring, make sure that liquid such as water and oil does not 

intrude from the tip of cable.

• 

When bending the cable during wiring, secure the cable radius of 

30 mm at the minimum.

• 

Use the dedicated actuators only. Other actuators will cause 

damage to the switch.

(Type 

SG-K24

)

Adjusting the Angle Adjustable (vertical/horizontal) Actuator

• 

Using the angle adjustment screw (M3 hexagon socket set screw), the actuator angle can 

be adjusted up to 20°(refer to dimensions).

• 

The larger the actuator angle, the smaller the applicable radius of the door swing.

After installing the actuator, open the door. Then adjust the actuator angle so that the 

actuator enters the entry slot of the safety switch properly.

• 

After adjusting the actuator angle, apply loctite or the like on the adjustment screw to 

prevent loosening.

• 

Use screw locking agent that is compatible with the base material.

Base: PA66 (66 nylon) of glass reinforced grade

Angle adjustment screws: stainless steel

• 

Do not mount the interlock switch facing down as shown in 

the figure on the right. The key may fall due to vibration.

Key

Be sure to take the following precautions. Otherwise, 

failure or damage may occur.

• When using the key, insert the key all the way.

• Do not apply a rotative force when inserting or removing 

the key. Also, do not pull the key during operation. 

Otherwise failure or damage may occur.

• 

Other than the standard key, there are 15 key variations. 

Be sure to use a key and cylinder with the same number.

•  Do  not  apply  excessive  force  to  the  key.  Otherwise 

failure or damage may occur.

• With the key in the UNLOCK position, do not turn the 

key to the LOCK position with the actuator removed 

(door open). Otherwise failure or damage may occur.

(Type 

SG-B2-K□-L5

)

For the Rear Unlock Button

•  The  Rear  Unlock  Button  is  used  for  an  emergency 

escape when the worker is confined in the safety 

hedge (the dangerous area).

•  The  lock  is  released  when  the  Rear  Unlock  Button  is 

pressed, and the door can be opened.

• To  return  to  locked  status,  pull  back  the  button.  While 

the Rear Unlock Button is depressed, the main circuit 

remains open and the door is unlocked.

Mounting Directions of the SG-B2 Head

• 

When replacing the 

SG-B2

 head, make sure that no foreign object enters into the safety 

switch. Tighten the screws tightly, without leaving space between the head and body, 

otherwise the safety switch may malfunction.

Don't remove the screws of head expect when the mouting directions of head is changed.

• 

After installing the manual rear unlocking button, apply Loctite to the screw so that the 

screw does not become loose. The base is made of glass-reinforced PA66 (66 nylon). The 

mounting screw is iron. Take the compatibility of plastic material and Loctite into 

consideration.

• 

Regardless of door types, do not use the safety switch as a door stop.

Install a mechanical door stop to the end of the door to protect the safety switch against 

excessive force.

• Mount the actuator so that it will not hit the operator when the door is open, otherwise injury may 

be cvaused.

• Turn off the power to the safety switch before starting installation, removal, wiring, maintenance, 

and inspection on the safety switch. Failure to turn power off may cause electrical shocks or fire 

hazard.

• Mount the actuator so that it will not hit the operator when the door is open, otherwise injury may 

be cvaused.

• Pay attention to the management of spare actuator. Safety function of door interlock switch will 

be lost in case the spare actuator is inserted into the interlock switch.

•  Ensure  that  the  actuator  is  firmly  fastened  to  the  door  (welding,  rivet,  special  screw)  in  the 

appropriate location, so that the actuator cannot be removed easily.

• Do not cut or remodel the actuator, otherwise failure will occur.

• If multiple safety components are wired in series, the Performance Level to EN ISO 13849-1 will 

be reduced due to the restricted error detection under certain circumstance.

• The entire concept of the control system, in which the safety component is integrated, must be 

validated to EN ISO 13849-2.

• 

Turn off the power to the safety switch before starting installation, removal, wiring, 

maintenance, and inspection on the safety switch. Failure to turn power off may cause 

electrical shocks or fire hazard.

• 

Do not disassemble or modify the switch. Also do not attempt to disable the interlock switch 

function, otherwise a breakdown or an accident will result.

• 

Install the 

SG-B2

 to ensure that a worker can operate the Rear Unlock Button from inside 

the safety hedge (the dangerous area). It is dangerous to install the 

SG-B2

 in the position 

where the Rear Unlock Button can be operated from outside the the safety hedge (the 

dangerous area), because it is possible to unlock while the machine is operating.

• 

Use hand to press the button, and do not use a tool. Do not apply excessive force to the 

Rear Unlock Button.

The values shown above are based on the condition that the actuator enters and exits the actuator 

entry slot smoothly when the door is closed or opened. Since there may be deviation or dislocation 

of the hinged door, make sure of correct operation in the actual application before installation.

SG-K21A / SG-K22A

• When there is a displacement of safety switch and actuator, the actuator may hit the entry 

slot of safety switch hardly, thus damaging the entry slot and actuator. The rubber 

cushions on the actuator prevent the actuator from damaging the entry slit by absorbing 

the shock with movement flexibility. Do not, however, exert excessive shocks, otherwise 

the failure of safety switch may be caused. 

•  The  rubber  cushions  may  deteriorate  depending  on  the  operating  environment  and 

conditions. 

Immediately replace the deformed or cracked rubber cushions with new ones.

Actuator Mounting Referance Position

• As shown below, the mounting reference position of the actuator inserted into the safety 

switch is:

The actuator and actuator cover touches the actuator stop placed on the safety switch 

lightly.

(After mounting the actuator, remove the actuator stop from the safety switch.)

Actuator Mounting Tolerance

• Mounting tolerance of the actuator is 1.0 mm in the 

four lateral directions.

• When closing the door, the actuator is inserted and 

locked within a certain distance from the reference 

position. After the actuator has been locked, the 

contact operation is not affected by the actuator 

movement in the locked state.

Minimum Radius of Hinged Door

•  When  using  the  safety  switch  for  a  hinged  door,  the  minimum  radius  of  the  applicable 

door is shown in the following figures.

Door Hinge

Door Hinge

Door Hinge

Door Hinge

R1

Minimum Radius

R3

Minimum Radius

R2

Minimum Radius

R4

Minimum Radius

When the center of the hinged door is 

on the extension line of the actuator 

mounting surfase.

When the center of the hinged door is on 

the extension line of the contact surface of 

actuator and safety switch.

1.8 to 2.2 N∙m

Screw Tightening Torque

For mounting the safety switch (M4 screw) *5

0.9 to 1.1 N∙m

For mounting the 

SG-B2

 head (M3)

0.5 to 0.7 N∙m

For mounting the manual rear unlocking button (M3 sems screw)

1.8 to 2.2 N∙m

0.8 to 1.2 N∙m

1.0 to 1.5 N∙m

1.0 to 1.5 N∙m

For mounting the actuator

(

SG-K21

: two M4 screws) *5

(

SG-K22

: two M4 Phillips screws)

(

SG-K21A 

SG-K22A

: two M4 screws) *5,6

(

SG-K24

: two M4 screws) *5

Name or Use

M4 mounting hole

Door

M4 Screw

Rubber Cushions

Washer

*5: The above recommended tightening torques of the mounting screws are 

the values confirmed with hex socket head bolts.

When other screws are used and tightened to a smaller torque, make 

sure that the screws do not come loose after mounting.

*6: In the case of 

SG-K21A

 or 

SG-K22A

, Using two M4 screws and two 

attached washers, fasten the actuator securely on the door.

CAUTION

(Actuator Completely Inserted)

(Actuator Pulled Out)

Contact Operation(reference)

Approx. 3.3 (Lock)

UNLOCK

LOCK

Contact Closed

Type *1

Contact Congifiguration

Contact Open

  

Approx.26.4 (Travel:mm)

0 (Actuator Mounting Reference Position)

Approx. 

5.3

  

Approx.

6.9

PK/WH

PK

21

11

BN/WH

BN

BU/WH

OG/WH

22

12

51

41

52

42

PK

23

11

PK/WH

BN/WH

BN

BU/WH

OG/WH

12

24

41

53

42

54

The A

ctuator is inserted, and 

SG-B2

 is locked.

Monitor Circuit:

Monitor Circuit:

Monitor Circuit:

Monitor Circuit:

Monitor Circuit:

Monitor Circuit:

SG-B2-□-C

SG-B2-□-D

11-12

23-24

41-42

53-54

11-12

21-22

41-42

51-52

BK

WH

A2

A1

(-)

(+)

Contact operation shows the 

SG-K21

 actuator.

(For other actuators, add 1.3 mm 

to contact operation.)

When using the outputs from the 

SG-B2

 safety switch as inputs to 

safety circuits,connect the door 

monitor circuits (11-12, 21-22) 

and lock monitor circuits(41-42, 

51-52) in series. (GS-ET-19)

Wiring

• 

Cable specifications UL style 2464 (80

 300V)

12c × No.22 AWG

• 

Wire identification

Wires are identified by the color and white line printed on 

the wire.

• 

Do not use wire which is Black, White, Gray, Gray / 

White.

Terminal Number Identification

• 

When wiring, the terminal number on each contact is 

identified by wire color.

The following shows the identification of terminal number

• 

When wiring, cut unnecessary wires such as dummy 

insulator (white) and/or unused wires to avoid incorrect 

wiring.

Note: Use the attached 

slot plug to close the 

unused actuator 

entry slot.

* Mounting pitch is set to 12 mm in factory. When setting 

the mounting pitch to 20 mm, widen the pitch of rubber 

cushions to 20 mm.

* The actuator has movement flexibility to the directions 

shown in  B  .

* When the mounting pitch is 12 mm (factory setting), the actuator 

has movement flexibility to the directions shown in   A   and   B  .

* When the mounting pitch is 20 mm, the actuator has movement 

flexibility to the directions shown in  B .  Side the rubber cushions 

together with the screws.

*7  The actuator stop and The 

Stopper film 

are used when adjusting the actuator position. 

Remove after the actuator position is determined.

*8  The direction of adjustable angle can be changed (vertical or horizontal) by changing the 

insertion direction of the joint (white plastic part).

Do not lose the joints. Actuators do not operate normally without a joint.

9

Contact infomation for CE

Panasonic Marketing Europe GmbH Panasonic Testing Center

Winsbergring 15, 22525 Hamburg,Germany

http://panasonic.net/id/pidsx/global

PRINTED IN JAPAN

© Panasonic Industrial Devices SUNX Co., Ltd. 2016