file:///C|/Documents and Settings/lopez/Pulpit/SHMZ1200/technics SH-MZ1200EB_EG_EK_PP_GN/s0701000000.html
●
VR1029:
High-tone input control (HIGH) (CH2)
●
VR1031:
High-tone input control (HIGH) (CH3)
●
VR1033:
High-tone input control (HIGH) (CH4)
●
VR1035:
Mid-tone input control (MID) (CH1)
●
VR1036:
High-tone input control (HIGH) (CH1)
●
VR1037:
Output effect control (SEND)
●
VR2001:
Monitor level volume control (LEVEL)
●
VR2003:
Master level volume control
(MASTER LEVEL)
●
VR2007:
Monitor mixing control (MIXING)
●
VR2009:
Master balance control
(MASTER BALANCE)
●
Indicated voltage values are the standard values for the unit measured by the DC electronic circuit tester (high-impedance) with the chassis taken as standard. Therefore, there may exist some errors in the voltage values, depending on theinternalimpedanceofthe DC circuit tester.
●
No mark: All VR is set as a center position.
●
Signal Line
file:///C|/Documents and Settings/lopez/Pulpit/SHMZ1200/technics SH-MZ1200EB_EG_EK_PP_GN/s0701000000.html (4 of 6)08-09-30 17:50:36