Fig. 2-1.
2.2. Grounding for electrostatic breakdown prevention
2.2.1. Human body grounding
Use the anti-static wrist strap to discharge the static electricity from your body. Refer to
Fig. 2-2.
Fig. 2-2.
2.2.2. Work table grounding
Put a conductive material (sheet) or steel sheet on the area where the MD unit (optical pickup) is placed, and
ground the sheet. Refer to
Fig. 2-3.
Fig. 2-3.
Caution:
The static electricity of your clothes will not be grounded through the wrist strap.
So take care not to let your clothes touch the MD unit (optical pickup).
3. Precaution of Laser Diode