4. When entering the main unit’s key check mode, “KEY JP” will be displayed.
When “KEY JP” is displayed, press
,
,
, VOL (+/-) keys and set
the HOLD switch to OFF (no order). Then, “KEY OK” will be displayed.
Note:
If “KEY OK” is not displayed, check the following voltage for each key.
Key
Test point
ON
OFF
IC201-35 pin
0V
2.3V
HOLD
TPX110
2.3V
0V
VOL +
TP307
0V
2.3V
VOL -
TP307
0.6V
2.3V
TP307
1.2V
2.3V
TP307
1.7V
2.3V
To exit the main unit’s key check mode, remove the battery.
Note:
Refer to “Printed Circuit Board and Wiring Connection Diagram” for the test
points.
7. Troubleshooting Guide