• Place the cooker upside down on a rubber sheet, then
insert the screwdriver upright for about 30 - 40 mm.,
as shown in the right figure.
• Turn the screwdriver in arrow direction to remove the
body, as shown in the right figure.
• Do not knock at the screwdriver, othewise the parts
contacted with screwdriver will be damaged.
Please follow the above procedures to remove.
4.
Note :
• For connectors or thing like this, please pull
outward directly. If pulled out in different directions,
the coil may be damaged or P.C.B. cracks due to
the pressure applied on it.
• When pulling out the fastening terminal, please
press the pin down in arrow direction while pulling.
Otherwise, the terminal can not be pulled out.
Note :
Please wear an anti-static wring strap or take relative
measures to prevent electric shock.
Remove the body of cooker
Remove the wiring of P.C.B. component
Remove the P.C.B. base (comp.)
• Pull out each connector with a pincers.
• Pull out the fastening terminals (3 places) with a
pincers.
5.
• Remove the fire-retardant tape attached on the P.C.B.
• Unplug the wiring connected to P.C.B.
• Remove the retaining screw on P.C.B. base (3 places).
• Take out the P.C.B. base directly with hand.
• Remove another fire-retardant tape attached on the
P.C.B.
6.