7
Drawing No.
Parts on the P.C.B.
Pan
Outer lid comp.
AC cord
Terminal
Thermal fuse
Pan sensor
Warming heater
Cast heater
Lid heater
Malfunctioned
component
Symptom
Cooking LED
lights up
If the fuse melts, check and remove
the cause firstly, then replace the
malfunctioned part.
This may occur due to user’s
improper measurement or
insufficient loosening of rice.
Check that there is on dirt or foreign
substances stuck to the surface of
the pan sensor.
This may occur by unplugging or
insufficient loosening of rice.
This may occur when the lid is kept open
for a long time, insufficient loosening of
rice or falling of Keep Warm pin.
Cooking LED
does not light up
LED does not
operate at all
Indicates
“H01” on LCD.
Indicates
“H02” on LCD.
Indicates
“H06” on LCD.
Indicates
“H05” on LCD.
Cannot cook rice correctly (stops
early or cooking is uneven, etc.)
Does not cook
Rice on bottom of the inner pan
is scorched
Keep Warm temperature is high
(over 78 C)
Keep Warm temperature is low
(below 68 C)
Droplets fall onto the surface of rice
The surface of rice dries up
The bottom of warm jar
melts and fires
Does not
keep warm
Keep Warm
LED lights up
Unit
description
15 23 44 48 48 54 61 6 22
Refer to page 9,10 when
the malfunctioned parts
are supposed to be on
the P.C.B..
SR-MG102, 182
Summary of Contents for SR-MG102
Page 2: ...2 SR MG102 182 Accessory Scoop Measuring cup Steaming basket Except SR DG102 Power cord ...
Page 3: ...3 1 Circuit Diagram SR MG102 182 SR MG102 182 ...
Page 5: ...5 3 Wiring Diagram SR MG102 182 SR MG102 182 ...
Page 6: ...6 SR MG102 182 ...
Page 8: ...8 FUZZY MICROCOMPUTER SR DE182 SR MG102 182 ...
Page 11: ...11 9 Replacing of P C B Comp SR MG102 182 ...
Page 12: ...12 SR MG102 182 ...
Page 13: ...13 SR MG102 182 ...
Page 14: ...14 SR MG102 182 ...
Page 15: ...15 SR MG102 182 ...
Page 17: ...17 1 7 2 5 6 3 4 13 Packing View SR MG102 182 ...