74
Screen Description
Time (HH:MM:SS):
Displays time of internal clock.
Date
(YYYY/MM/DD):
Displays date of internal clock.
SNTP Server IP
Displays an IP address of SNTP server that executes time
synchronization.
SNTP Polling Interval
Displays an interval of time synchronization with SNTP server.
Time Zone:
Displays time zone.
Daylight Saving:
Displays the application status of Daylight Saving (Summer time).
Available commands are listed below.
C Set time of internal clock of this Switching Hub.
Press "C." The command prompt changes to "Enter Date(Year) >" and enter a year.
Then, the command prompt changes to "Enter Date(Month) >" and enter a
month. Then, the command prompt changes to "Enter Date(Day) >" and enter a
day. Then, the command prompt changes to "Enter Time(Hour) >" and enter an
hour. Then, the command prompt changes to "Enter Time(Minute) >" and enter a
minute. Then, the command prompt changes to "Enter Time(Sec) >" and enter a
second.
P Set an IP address of SNTP server.
Press "P." The command prompt changes to "Enter new IP address>." Enter an IP
address of SNTP server.
I Set an interval time for SNTP synchronization.
Press "I." The command prompt changes to "Enter Interval Time>." Enter an
interval of time synchronization with SNTP server with a value of 1 to 1440
(minutes).
The factory default setting is 1440 minutes (1 day).
E Set the application of Daylight Saving (Summer time).
Press "E." The command prompt changes to "Enable or Disable Daylight Saving
(E/D)>." Enter "E" to apply, or "D" not to apply Daylight Saving.
But, in case time zone is set to where daylight saving is not applied, this
configuration is not available.
When this Switching Hub is used domestically, this configuration is not required.
Z Set time zone.
Press "Z" to open a list of time zones. Specify a time zone you wish to set.
The factory default setting is "(GMT+09:00) Osaka, Sapporo, Tokyo."
Q Return to the previous menu.
Note: In case SNTP server is located outside of firewall, connection with
SNTP server may not be possible depending on settings by system
administrator.
For details, ask to your system administrator.
If you wish to disable time synchronization function, set SNTP server
IP to 0.0.0.0 and reboot the device.
Summary of Contents for Switch-M12PWR
Page 17: ...17 Fig 2 2 Mounting to Wall ...
Page 20: ...20 function does not work Therefore use a cross cable to connect them ...
Page 30: ...30 ...
Page 36: ...36 ...
Page 49: ...49 ...
Page 69: ...69 ...
Page 81: ...81 setting and the management VLAN status of VLAN ID 1 is UP ...
Page 96: ...96 Press S Q Return to the previous menu ...
Page 98: ...98 ...
Page 122: ...122 Q Return to the previous menu ...
Page 125: ...125 ...
Page 130: ...130 ICMP Type Displays the ICMP type ...
Page 156: ...156 Threshold Displays the threshold of the number of packets per second ...
Page 173: ...173 Fig 4 7 49 Display of values accumulated after resetting the counters ...
Page 185: ...185 Q Return to the previous menu ...
Page 211: ...211 Q Return to the previous menu ...
Page 232: ...232 IEEE8021 PAE MIB IEEE802 1X IEEE8023 LAG MIB IEEE 802 3ad ...
Page 237: ...237 IEEE 802 3af standard ...
Page 240: ...240 P0813 1084 ...