background image

12

Port LED (Left)

Port LED (Right)

• Port LED (Left)

 

Green Light (when the LOOP HISTORY LED  is off)

 

 

 

 

: Link is established at 10/100/1000 Mbps.

 

Green Light (when the LOOP HISTORY LED is Blink)

 

 

 

 

: Within three days after a loop has been eliminated

 

Green Blink    

: Data is being sent/received at 10/100/1000 Mbps.

 

Orange Light  

: Shut off by the loop detection/shutoff function 

 

Off 

 

 

: No terminal is connected or the ECO mode is set.

• Port LED (Right)

 

Green Light   

: Power is supplied normally. (Ports 1 to 4 only)

 

Orange Blink  

: Overload power supply (Ports 1 to 4 only) or overload in 

                                              a single port
 

Off 

 

 

: Power is not supplied or PoE receiving equipment is not

                                             connected.

Part Names and Functions

2

Summary of Contents for Switch-M5eGLPWR+ Series

Page 1: ...ing Hub Please read the Important Safety Instructions on pages from 3 to 5 Any problems or damage resulting from disassembly of this Switching Hub by customers are not covered by the warranty I0716 10719 Printed in Japan Switch M5eGLPWR Model No PN28058 TH PN28058 MY PN28058 ID PN28058 SG 2 12 7 Higashi Shimbashi Minato ku Tokyo Japan 105 0021 2019 ...

Page 2: ... Outline 1 1 Features 1 2 Specifications 1 3 Accessories 1 4 Basic operation 2 Part Names and Functions 2 1 LED display change 2 2 PoE power supply function 3 Installation and Configuration 3 1 Mounting to rack 3 2 Configuration of IP address Basic Troubleshooting 3 6 7 7 8 9 9 10 13 14 15 15 16 18 ...

Page 3: ... Do not disassemble and or modify this Switching Hub Deviation could lead to fire electric shock and or equipment failure Do not damage the power cord Do not bend too tightly stretch twist bundle Do not unplug nor plug in the power plug with wet hands Deviation could lead to electrical shock and or equipment failure Do not insert nor drop any foreign objects such as metal or readily combustible th...

Page 4: ...ction Unplug the power cord if the STATUS LED blinks in orange system fault Deviation such as keeping connected for a long time could lead to fire Handle the Switching Hub carefully so that fingers or hands may not be damaged by twisted pair port SFP extension slot console port or power cord hook block Do not connect any other devices except for 10BASE T 100BASE TX 1000BASE T devices to the twiste...

Page 5: ...Communications failures might be generated due to causes such as malfunctions or misoperations while the Switching Hub is being used When using this Switching Hub for applications which require extremely high reliability be careful to expend all possible means to ensure safety and reliability This Switching Hub was not designed nor manufactured with the intention that it be used for applications i...

Page 6: ... temperature exceeding the specifications environment Strong vibration and or strong shock Please use this Switching Hub in place where ambient temperature is from 0 to 50 C Failure to satisfy the conditions above may result in a fire electric shock equipment failure and or malfunction Such events are not covered by the warranty Do not block the ventilator of the Switching Hub Blocked ventilator i...

Page 7: ...hanges and verifications of the Switching Hub Remotely configure the PoE settings for each port Ports 1 to 4 Equipped with energy efficient Ethernet EEE conforming to IEEE802 3az LPI When there is no data transmission at link up the energy saving state automatically starts so that power consumption can be reduced on each port Embedded power saving mode detects the connection status automatically a...

Page 8: ... v2 WEB control screen Power supply function Ports 1 to 4 support the IEEE802 3at compatible power supply function Maximum power supply 30 W per port 62 W in total Power supply method Alternative A Using signal line 1 2 3 6 Others IEEE802 1D spanning tree IEEE802 1w rapid spanning tree IEEE802 1X authentication function supported port base authentication Port monitoring ring protocol IGMP snooping...

Page 9: ...100 240 V 50 60 Hz When power is supplied all the LEDs are turned ON Then POWER LED Power lights in green STATUS ECO LED Status ECO mode lights in orange and self diagnosis of hardware is executed On completion of self diagnosis POWER LED Power STATUS ECO LED Status ECO mode and TEMP LED Temperature sensor light in green and the Switching Hub starts operation as a Switching Hub As this Switching H...

Page 10: ... bridge and Switching Hub can be connected to this port Install the device so that the length of twisted pair cable CAT5e or above becomes 100 m or less 10 100 1000BASE T port ports 5 6 Devices such as 10 100 1000BASE T terminal hub repeater bridge and Switching Hub can be connected to this port Install the device so that the length of twisted pair cable CAT5e or above becomes 100 m or less SFP ex...

Page 11: ...n the range from 47 to 62 W Orange Blink A single port s power supply is exceeding the upper limit or the total power supply of the Switching Hub is exceeding 62 W FAN LED Fan sensor Green Light System is operating normally Orange Blink Fan fault is occurring TEMP LED Temperature sensor Green Light The system is normally operating Orange Blink The temperature exceeded the set threshold of the inte...

Page 12: ...ted Green Blink Data is being sent received at 10 100 1000 Mbps Orange Light Shut off by the loop detection shutoff function Off No terminal is connected or the ECO mode is set Port LED Right Green Light Power is supplied normally Ports 1 to 4 only Orange Blink Overload power supply Ports 1 to 4 only or overload in a single port Off Power is not supplied or PoE receiving equipment is not connected...

Page 13: ...tting OFF ON by using a console cable for detail see the attached CD ROM The default setting is ON If you wish to clear loop detection history turn OFF once the power supply of the Switching Hub and turn it ON again Then loop detection history is deleted The Switching Hub can hold up to 64 loop history logs Two types of Base modes The mode at the start is called Base mode There are two types of Ba...

Page 14: ...on 1 Some PoE powered devices may have a large difference in power consumption between their maximum power use condition and normal condition Carefully configure them so that the upper limit of power supply will not be exceeded 2 If you don t set a priority for power supply or if the same priority is given note that the power supply priority is assigned to the ports in ascending order of the port ...

Page 15: ...ount brackets to the Switching Hub to fix the mount brackets to the four holes on a side of the Switching Hubs Then use the supplied two connection brackets and eight screws for fixing the connection brackets to securely fix the connection brackets to the connection screw holes on the front and back panels and then install the Switching Hubs on the rack Right side Left side Screw holes for fixing ...

Page 16: ...select System I P Configuration The screen to enter some addresses is displayed Screen 4 5 Press I to set an IP Address press M to set a Subnet Mask or press G to set a Default Gateway Then enter the specified address Screen 4 6 After completing the settings select Q uit to previous menu twice to return to Main Menu Screen 2 Here select Save Configuration to F lash Screen 5 and the command prompt ...

Page 17: ... Screen 1 Screen 2 Screen 3 Screen 4 Screen 5 For the following please see the PDF version Operating Instructions in CD ROM Detailed configuration and management methods using the CLI Configuration and management method from ZEQUO assist Plus ...

Page 18: ...gs The Port LED Right lights in orange Loop is occurring By removing the loop orange LED will be turned off LOOP HISTORY LED Blinks in orange This is to notify that there is a port in which a loop is occurring or has been removed within 3 days Communications are slow Are the communication speed and mode settings correct If the proper communication mode signal cannot be obtained apply half duplex m...

Page 19: ...h the IEEE802 3at 30W standard Port LED Right is blinking orange Ensure that the total power supply demand from PoE powered devices does not exceed 62 W When the power supply is suddenly shut off It is likely that a PoE powered device in use has a different power consumption in normal operation and standby states After turning on the PoE LED power supply mode confirm that a single port is not over...