background image

Page 2 of  13

Model
Name

Model
No.

Switch-M8eGi

PN28080i-ID

Product Specification

401-28080i-ID-SP01

Panasonic Life Solutions Networks Co., Ltd.

Date revised

Date issued

May. 26, 2020

3. Rated/Environmental Conditions

4-1. Form and materials/colors

4-2. Mass(Weight)

1,100g

4. Form

Dimensions

:44mm(Height)×210mm(Width)×130mm(Depth)
(Excluding protruding sections)

Case material

:SECC

Color

: Main unit: Green 03, Front face: Black 03, 

Face plate label: Black 04

3-1. Power supply

AC100-240V, 50/60Hz, 0.5A (with a built-in power supply)

3-2. Power consumption

3-3. Operating environment

Temperature: 0 - 60℃
Humidity:      20 - 80%RH (no condensation)

3-4. Storage environment

Temperature: -20 - 70℃
Humidity:      10 - 90%RH (no condensation)

Normally, Max : 6.2W, Min : 2.4W

3-5. EMC compliance

CISPR 22 Class A
EN 55022 Class A
AS/NZS CISPR22 Class A
VCCI Class A
EN 61000-3-2, EN 61000-3-3
CISPR 24
EN 55024
IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, 
IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11 

3-6. Safety compliance

IEC 60950-1 
EN 60950-1

RoHS compliant

3-7. Environment compliance

Summary of Contents for Switch-M8eGi Series

Page 1: ...a loop detection history function which notifies when a loop occurs with the corresponding LED and enables a network administrator to identify the looped port after the loop is removed 6 Fanless desi...

Page 2: ...e plate label Black 04 3 1 Power supply AC100 240V 50 60Hz 0 5A with a built in power supply 3 2 Power consumption 3 3 Operating environment Temperature 0 60 Humidity 20 80 RH no condensation 3 4 Stor...

Page 3: ...EEE802 3az LPI When there is no data transmission at link up the energy saving state automatically starts so that power consumption can be reduced on each port Factory default Disable SFP extension sl...

Page 4: ...lay for the connection with a connected terminal Status mode Display for the 1000 Mbps transmission rate GIGA mode Display for the 100Mbps or 10 Mbps transmission rate Speed mode Display for the full...

Page 5: ...nk Off Green Light Off Port LED Left Right Port LED Left Port LED Right 5 Hardware Specifications Link is established Transmitting and receiving data No device connected Link is established at 1000Mbp...

Page 6: ...on status can be checked using the following functions 1 Function to display the CPU 2 SFP module status checking function DDM Digital Diagnostic Monitoring 6 3 Rebooting 6 2 Switching Hub Control 6 4...

Page 7: ...the power is turned OFF Loop shutoff time 60 to 86 400 sec Factory default setting 60 sec The set time Port LED lights up orange and the port shuts off Loop history retention time 3 days The LOOP HIS...

Page 8: ...n EAP MD5 TLS PEAP Authentication method Web based authentication Mac based authentication using IEEE 802 1X Web based authentication Dynamic VLAN function using IEEE 802 1X Guest VLAN using IEEE 802...

Page 9: ...mount brackets to the Switching Hub 8 8 Screw for fixing the connection bracket 8 9 Power cord CEE7 7 1 The attached power cord is dedicated for AC 100 240 V use 10 2 Accessories 8 2 2 Time setting SN...

Page 10: ...125 m Multi Mode Fiber 62 5 125 m Multi Mode Fiber Maximum transmission distance 550 m at 50 125 m 220 m at 62 5 125 m 11 1 1000BASE SX SFP Module i Model No PN54022 ID 11 2 1000BASE LX SFP Module i...

Page 11: ...orrosive and combustible gases Deviation could lead to fire electrical shock and or equipment failure 8 Do not place this Switching Hub under direct sunlight and or high temperature Deviation could le...

Page 12: ...use the optical signal to not be transmitted normally and cause misoperations and malfunctions If they are contaminated make sure to clean them off then connect them to the optical fiber ports 9 This...

Page 13: ...r use this Switching Hub in the environment in accordance with the specification High humidity Possible spilled liquid water Dusty Possible static charge such as carpet Under direct sunlight Possible...

Reviews: