1. Access the IIC mode and set the Aging Pattern to 1(white pattern) (Vset
adjustment pattern).
2. Set the picture adjustment items as follows.
·
Picture menu : Standard
·
Color temperature : Normal
·
Picture : 25
·
Aspect : Full
Test point
Volume
Level
TPSC1 (SC)
VR6601
(SC)
190V
±
7V
T
2
TPSC1 (SC)
VR6602
(SC)
165
±
10µ Sec
50
3. Connect the Oscilloscope to TPSC1 and adjust VR6601 for 190V
±
7V.
4. Connect the Oscilloscope to TPSC1 (T2) and adjust VR6602 for 165
±
10µ Sec.
Initialization Pulse Adjustment