installed.
3. After servicing, make the following leakage current checks to
prevent the customer from being exposed to shock hazards.
2.2. Touch-Current Check
1. Plug the AC cord directly into the AC outlet. Do not use an
isolation transformer for this check.
2. Connect a measuring network for touch currents between each
exposed metallic part on the set and a good earth ground such as
a water pipe, as shown in Figure 1.
3. Use Leakage Current Tester (Simpson 228 or equivalent) to
measure the potential across the measuring network.
4. Check each exposed metallic part, and measure the voltage at
each point.
5. Reserve the AC plug in the AC outlet and repeat each of the above
measure.
6. The potential at any point (TOUGH CURRENT) expressed as
voltage U
1
and U
2
, does not exceed the following values:
For a. c.: U
1
= 35 V (peak) and U
2
= 0.35 V (peak);
For d. c.: U
1
= 1.0 V,
Note:
The limit value of U
2
= 0.35 V (peak) for a. c. and U
1
= 1.0 V for d. c. correspond to the values 0.7
mA (peak) a. c. and 2.0 mA d. c.
The limit value U
1
= 35 V (peak) for a. c. correspond to the value 70 mA (peak) a. c. for
frequencies greater than 100 kHz.
7. In case a measurement is out of the limits specified, there is a
possibility of a shock hazard, and the equipment should be
repaired and rechecked before it is returned to the customer.
Figure 1
Summary of Contents for TH-37PA20AA
Page 20: ...4 TH 37PA20AA TH 37PA20FA TH 37PA20HA TH 37PA20MA TH 37PA20RA ...
Page 30: ...6 Mechanical Replacement Parts List 10 ...
Page 68: ...R483 ERG2FJS104D M 100KOHM J 2W 1 48 ...
Page 71: ...R1061 ERJ3GEYJ223 M 22KOHM J 1 16W 1 51 ...
Page 107: ...6 Mechanical Replacement Parts List 9 ...
Page 110: ...7 2 Electrical Replacement Parts List 12 ...
Page 144: ...R408 ERJ6GEYJ6R8 M 6 8 OHM J 1 10W 1 46 ...
Page 148: ...R1075 ERJ3GEYJ102 M 1KOHM J 1 16W 1 50 ...
Page 172: ...S300 K0F162B00002 SWITCH 1 74 ...
Page 287: ...2 Service Hint 7 TH 42PA20A TH 42PA20F TH 42PA20H TH 42PA20M TH 42PA20R ...
Page 288: ...8 TH 42PA20A TH 42PA20F TH 42PA20H TH 42PA20M TH 42PA20R ...
Page 308: ...7 3 Lead of wiring 3 ...
Page 309: ...7 4 Lead of wiring 4 ...
Page 315: ...9 3 Option Description ...
Page 316: ......
Page 317: ...10 CAT computer Aided Test mode ...
Page 330: ...17 Mechanical Replacement Parts List ...
Page 568: ...1 Applicable signals 4 TH 42PA20E TH 42PA20B ...
Page 572: ...5 Service Hint 8 TH 42PA20E TH 42PA20B ...
Page 578: ...7 Location of Lead Wiring 7 1 Lead of Wiring 1 7 2 Lead of wiring 2 14 TH 42PA20E TH 42PA20B ...
Page 579: ...7 3 Lead of wiring 3 15 TH 42PA20E TH 42PA20B ...
Page 580: ...7 4 Lead of wiring 4 7 5 Lead of wiring 5 16 TH 42PA20E TH 42PA20B ...
Page 586: ...22 TH 42PA20E TH 42PA20B ...
Page 587: ...9 3 Option Description 23 TH 42PA20E TH 42PA20B ...
Page 588: ...24 TH 42PA20E TH 42PA20B ...
Page 591: ...10 4 IIC mode structure following items value is sample data 27 TH 42PA20E TH 42PA20B ...