11.3. Sub bright adjustment
Instrument Name
Connection
Remarks
1.
PAL signal generator (or RF)
Connect to the input terminal
User setting: Normal
Procedure
Remarks
·
White balance adjustment is finished for each signal.
·
Do adjustments in a dark room.
·
Complete the adjustment within 10 minutes after the turn on electricity.
Turn on the power supply again when it is not possible to complete it by aging etc.
1.
Display the 10 step gray-scale pattern for adjusting sub-bright from video input.
2.
Use "Sub-Bright" in the <Sevice1> mode to adjust so the 6th section shows up and the
7th fades away.
Data
Sub-Bright data addresses
Sub-Bright (upper) A0-0116
Sub-Bright (lower) A0-0117
Picture menu: Dynamic
Color balance: Normal
ASPECT: 16:9
38
TH-37PA60H / TH-37PA60M / TH-42PA60A / TH-42PA60H / TH-42PA60M / TH-42PA60MT