11.3. Sub bright adjustment
Instrument Name
Connection
Remarks
1. PAL signal generator (or RF)
Connect to the input terminal User setting: Normal
Procedure
Remarks
-
Color balance adjustment is finished for each signal.
-
Do adjustments in a dark room.
-
Complete the adjustment within 10 minutes after the turn on electricity.
Turn on the power supply again when it is not possible to complete it by aging etc.
1. Display the pattern for adjusting subbright from video input.
2. Pull down SRQ of the panel D-Board to L.
3. Use "Sub-Bright" in the "Sevice-Menu1" mode to adjust so the top part of the step section in the
below diagram faintly shows up and the middle fades away.
Picture menu: Dynamic
Color balance: Normal
ASPECT: 16:9
* If using RF ch.E04,
(Sub-Bright test pattern),
adjust so the 6th section shows
up and the 7th fades away.
11.4. ABL adjustment