24
7.21. Remove the Front bracket
1. Unlock the cable clampers to free the cable.
2. Disconnect the connectors (A9, A11, A51 and A53). (See
section 7.7.)
3. Remove the screws (
×
3 ,
×
2
) and remove the
Front bracket.
7.22. Remove the G-Board, GS-
Board and GH-Board
1. Remove the Front bracket. (See section 7.21.)
2. Remove the screws (
×
3 ).
3. Remove the screws (
×
4 ).
4. Remove the Front shield case front.
5. Disconnect the connectors (GH11 and GS02, GS09).
6. Remove the screws (
×
2 ).
7. Remove the Front shield top.
8. Remove the GH-Board.
9. Remove the screws (
×
1
) and remove the GS-Board.
10. Remove the screws (
×
3 ).
11. Disconnect the connector (G51) and remove the G-
Board.
7.23. Remove the Plasma panel sec-
tion from the Cabinet assy
(glass)
1. Remove the stand brackets (left, right) fastening screw
(
×
1
each).
2. Remove the cabinet assy and the plasma panel fastening
screws (
×
8 ,
×
6 ).