1 Safety Precautions
1.1.
General Guidelines
1. When servicing, observe the original lead dress. If a short circuit is found, replace all parts which have been overheated or
damaged by the short circuit.
2. After servicing, see to it that all the protective devices such as insulation barriers, insulation papers shields are properly
installed.
3. After servicing, make the following leakage current checks to prevent the customer from being exposed to shock hazards.
4. When conducting repairs and servicing, do not attempt to modify the equipment, its parts or its materials.
5. When wiring units (with cables, flexible cables or lead wires) are supplied as repair parts and only one wire or some of the
wires have been broken or disconnected, do not attempt to repair or re-wire the units. Replace the entire wiring unit instead.
6. When conducting repairs and servicing, do not twist the Faston connectors but plug them straight in or unplug them straight
out.
1.1.1.
Leakage Current Cold Check
1. Unplug the AC cord and connect a jumper between the
two prongs on the plug.
2. Measure the resistance value, with an ohmmeter,
between the jumpered AC plug and each exposed
metallic cabinet part on the equipment such as
screwheads, connectors, control shafts, etc. When the
exposed metallic part has a return path to the chassis, the
reading should be 100 Mohm and over.
When the exposed metal does not have a return path to
the chassis, the reading must be
.
1.1.2.
Leakage Current Hot Check (See
Figure 1.)
1. Plug the AC cord directly into the AC outlet. Do not use
an isolation transformer for this check.
2. Connect a 1.5kohm, 10 watts resistor, in parallel with a
0.15
F capacitors, between each exposed metallic part
on the set and a good earth ground such as a water pipe,
as shown in Figure 1.
3. Use an AC voltmeter, with 1000 ohms/volt or more
sensitivity, to measure the potential across the resistor.
4. Check each exposed metallic part, and measure the
voltage at each point.
5. Reverse the AC plug in the AC outlet and repeat each of
the above measurements.
6. The potential at any point should not exceed 0.75 volts
RMS. A leakage current tester (Simpson Model 229 or
equivalent) may be used to make the hot checks, leakage
current must not exceed 1/2 milliamp. In case a
measurement is outside of the limits specified, there is a
possibility of a shock hazard, and the equipment should
be repaired and rechecked before it is returned to the
customer.
Figure 1
Summary of Contents for TH-L39EM6R
Page 26: ...TH L39EM6R 26 11 Schematic Diagram Model No TH L39EM6R A Board 1 12 ...
Page 27: ...Model No TH L39EM6R A Board 2 12 ...
Page 28: ...Model No TH L39EM6R A Board 3 12 ...
Page 29: ...Model No TH L39EM6R A Board 4 12 ...
Page 30: ...Model No TH L39EM6R A Board 5 12 ...
Page 31: ...Model No TH L39EM6R A Board 6 12 ...
Page 32: ...Model No TH L39EM6R A Board 7 12 ...
Page 33: ...Model No TH L39EM6R A Board 8 12 ...
Page 34: ...Model No TH L39EM6R A Board 9 12 ...
Page 35: ...Model No TH L39EM6R A Board 10 12 ...
Page 36: ...Model No TH L39EM6R A Board 11 12 ...
Page 37: ...Model No TH L39EM6R A Board 12 12 ...
Page 38: ...Model No TH L39EM6R GK Board ...
Page 39: ...Model No TH L39EM6R K Board ...
Page 40: ...Model No TH L39EM6R P Board 1 2 ...
Page 41: ...Model No TH L39EM6R P Board 2 2 ...
Page 42: ... 2 12 Printed Circuit Board Model No TH L39EM6R A Board Top Component Side TH L39EM6R ...
Page 43: ...Model No TH L39EM6R A Board Bottom Component Side ...
Page 44: ...Model No TH L39EM6R GK Board ...
Page 45: ...Model No TH L39EM6R K Board ...
Page 46: ...Model No TH L39EM6R P Board Top Component Side ...
Page 47: ...Model No TH L39EM6R P Board Bottom Component Side ...
Page 48: ...TH L39EM6R 8 13 Exploded View and Replacement Parts List Model No TH L39EM6R Parts Location ...
Page 49: ...Model No TH L39EM6R Packing Exploded View 1 ...