TH-42/50PX500U Self-check Function (Reset)
Diagnostic Procedures
Self-check is used to automatically check the status of the ICs that are controlled via the
IIC bus line. Under normal condition, the status is
OK.
A status indication other than OK
indicates a problem within a specific board
How to access the Self-check Screen (Reset)
To get into the Self-check mode, press and hold down the
VOLUME DOWN
button on
the front of the unit
,
and the
SLEEP
button on the remote control. Hold them down for at
least three seconds. The unit automatically tunes to channel 3. The word “SELF-
CHECK“ appears at the center of the screen for a few seconds, and then a graphic
OSD that resembles the one in the figure below appears.
How to exit the Self-check Screen
To exit the Self-check mode, press the power button in front of the unit for
approximately three seconds. The unit powers down and then powers back up in a few
seconds.