Troubleshooting
In case of suspected fault, please check the following conditions before sending the Alkaline Ionizer for inspection.
In addition, if there is any abnormal condition, do not dismantle the Alkaline Ionizer by yourself. Please contact a
dealer or subordinate service station of Panasonic for handling.
Phenomenon
Cause and method of disposal
Pages for
reference
W
ater signal indicator
Continuously flash
without lighting up, or
flash when in use.
Automatic cleaning will be conducted every 160 hours or if the
Alkaline Ionizer is not used for 12 hours.
(The water signal indicator is in red and flashing. There is warning sound.)
→
Please perform continuous water run through for about 18 seconds ~ 35 seconds.
After the completion of cartridge installation or replacement,
when the water has run through, the water signal indicator will
flash for 20 seconds ~ 30 seconds, then it will light up.
(“alkalineionwaterˮor“purifiedwaterˮ:blue;“weakacidicˮ:red)
→
Please perform water run through for about 10 L of purified
water (about 5 minutes). (To discharge the air in the cartridge)
Whether the water flow is insufficient? (It has to be more than 1.2 L/min.)
→Pleaseopenthewaterstopvalve.
Haveyoupresseddowntwobuttonsatthesametime?
(Thewaterqualityindicatorlightof“weakacidic”flashes,when
water runs through, the water signal indicator is in red and flashing.)
→Pleasekeepatthestopwaterstatus,press
Weak Acidic
and
Alkaline
Adjusting pH(3sec.)
,andtherewillbeawarningsoundof“PI-”.
EN22
—
EN21
EN17
—
The display light is off in
operation, and the water
outflow stops.
HastheAlkalineIonizerbeencontinuouslyusedformorethan
10minutesat(“alkalineionwater(strong)”or“weakacidic”mode.If
thehydrogenmodeisused,thetimeof“alkalineionwater(mild)”or
“alkalineionwater(strong)”shallbelessthan10minutes.
Inaddition,inaccordancewithdifferentwaterqualityorenvironment,
thewateroutflowwillbestoppedautomaticallytoprotecttheAlkaline
Ionizer.(Awarningsoundof“PI-PI-PI-ˮwillbemade.)
→Pleasepress
Water
Stop/Flow
again after 3 minutes.
The flow is reduced due to the change of water pressure. (Has to
be more than 1.2 L /min.)
→Pleaseuseafterchoosingwaterqualityagain.
EN8
EN16, EN17
Red light
⇔
blue light
flashes alternately, and there
is no water outflow. (The
buttons cannot be operated.)
There is water leakage in the main unit.
→Pleaseunplugthepowerplugandclosethewaterstop
valve,thencontactadealerorsubordinateservicestationof
Panasonic for handling.
EN9
W
ater quality indicator lights
After using “purified water” or
“weak acidic” mode, the display
light will change into “alkaline
ion water (weak) ~ (strong)”
Istheprioritymodeofalkalineionwaterselected?
→Tocancelthissetup,pleasepress
Purified
without water
supplyuntilthereisthewarningsoundof“PI-”.(About3
seconds)
EN17
When using “alkaline ion waterˮ or
“weak acidicˮ mode, the hydrogen
adjustment light and “weak acidicˮ
indicator light will flash, the
“purified waterˮ indicator light will
light up and the water outflow will
stop. (Buttons cannot be operated.)
Inaccordancewithdifferentwaterqualityorenvironment,the
wateroutflowwillautomaticallystoptoprotecttheAlkalineIonizer.
(Awarningsoundof“Pl-”willbemadeforthreetimes.)
→Itwillautomaticallyrecoverafterabout30minutes.
If water runs through before the Alkaline Ionizer returns to
normalmode,“purifiedwaterˮwillflowout.Ifithasnotbeen
recovered,pleaseunplugpowerplugfromthepoweroutlet,
then re-plug.
—
Purified
Reset
Adjusting pH
Filter Replacement
Low
High
Water
Stop/Flow
Alkaline
Weak Acidic
Adjusting pH(3sec.)
(3 sec.)
Purified
Reset
Adjusting pH
Filter Replacement
Low
High
Alkaline
Weak Acidic
Adjusting pH(3sec.)
(3 sec.)
Engl
is
h
When necessary
EN25
01_TK-AB50-ZEX_ZMA_EN.indd 24
2018/09/28 14:50:09