EN45
Troubleshooting
Engli
sh
If you think that something is wrong with the Alkaline Ionizer, check out the following points before
requesting repairs. If you decide that trouble has occurred, do NOT attempt to disassemble and repair
the Alkaline Ionizer yourself, but contact your dealer.
Sometimes suspected trouble is remedied by disconnecting the power plug and then re-connecting
it.
When the LCD display shows the following:
Symptom
Check following point
Reference
page
English is not displayed on
the LCD.
This is because the English display mode has not been
selected.
Take the steps to switch to the English display mode.
EN19
English is displayed on the
LCD.
This is because switching to the English display mode has
been undertaken.
Take the steps to switch the display language, and return to
the Chinese display mode.
EN19
The displays in the setting
and check modes are not in
English.
The displays cannot be shown in English in the setting and
check modes.
(This is not a malfunction.)
EN19
No display at all or LCD
display is cleared suddenly
The display is cleared automatically when the Alkaline Ionizer
is not being used.
(This is not a malfunction.)
EN19
Is the power plug disconnected?
If it is, connect it.
–
The “Preparation time”
display blinks
This display appears for about 20 seconds when water runs
through the Alkaline Ionizer immediately after installation or
cartridge replacement.
The air inside the cartridge is being expelled. Keep running
the water for 3 or 4 minutes.
EN9
EN37
The “Electrode cleaning”
display blinks
The electrodes are being automatically cleaned.
Keep running the water for about 15 seconds.
EN40
The display changes to
“Alkaline” after “Alkaline 4
(Strongly Alkaline)”, “Weak
Acidic” or “Purifi ed Water”
was used
When the faucet is turned off after the Alkaline Ionizer is used
at the “Alkaline 4 (Strongly Alkaline)”, “Weak Acidic” or “Purifi ed
Water” setting, the “Alkaline” setting is automatically restored.
(This is not a malfunction.)
EN21
The display does not return
to “Alkaline” after the
Alkaline Ionizer was used at
the “Purifi ed Water” setting
Has “OFF” been selected for “Alkaline priority” so that the
Alkaline setting will not be returned?
Set “Alkaline priority” to ON.
EN32
Does this happen while the Continue lamp is lighted?
(This is not a malfunction. The “Alkaline” setting will be
returned after about 10 minutes.)
EN21
When the water fl ow is
reduced at the faucet during
use, the display suddenly
changes to “Cartridge life”
This happens when the water fl ow is reduced too much or the
fl ow is diminished due to a change in the water pressure.
When using the Alkaline Ionizer at the “Alkaline 4 (Strongly
Alkaline)”, “Weak Acidic” or “Purifi ed Water” setting, press
the water quality selector button again, turn on the faucet,
and adjust the fl ow.
EN22
Continued on next page
TK-AS66-ZEX̲En.indb 45
TK-AS66-ZEX̲En.indb 45
2017/01/30 15:04:26
2017/01/30 15:04:26