ADJUSTMENT PROCEDURE
Item/Preparation
Adjustments
+B SET-UP
1. Receive a Greyscale signal.
2. Set the controls :-
Brightness
Minimum
Contrast
Minimum
Volume
Minimum
1. Set the +B voltage up as follows :-
Adjust R811 so that B2 shows 148V±1V
2. Confirm the following voltages.
B9
5
±
0,25V B10
5
± 0,25V
B5
12
± 0,5V
B11
33
± 1,5V
B4
16
± 1V
B7
8
± 0,5V
B12 26
± 1V
B8
5,5
±
0,5V
B3
41
± 1V
B13
15
±
1V
B1
200
± 10V
B14
-15
± 1V
Cut-Off / Ug2 Test
1. Receive a Greyscale signal.
2. Degauss the tube externally.
3. Set the TV into Service Mode 1.
4. Select Cutoff mode.
To adjust Cutoff, connect an oscilloscope to the blue
cathode, adjust "cutoff" value using the "YELLOW" and
"BLUE" buttons until the black level is 160V±5V press
"STR" to store the value. Remove the oscilloscope.
Select Ug2 adjustment and adjust the screen VR until the
display shows "O.K."
REGLAGES
Préparation
Réglages
+B Réglages
1. Appliquer une mire à carreaux N/B.
2. Régler les contrôles suivants :-
Lumière
Minimum
Contraste
Minimum
Volume
Minimum
1. Régler les tensions +B comme suit: Régler R811 tel
que la tension B2 soit de 148V±1V.Confirmer le
réglage -:
B9
5
± 0,25V B10
5
± 0,25V
B5
12 ± 0,5V
B11
33 ± 1,5V
B4
16 ± 1V
B7
8
± 0,5V
B12 26 ± 1V
B8
5,5 ±
0,5V
B3
41 ± 1V
B13
15 ± 1V
B1
200± 10V
B14
-15 ± 1V
Cut-Off / Ug2 Test
1. Appliquer une mire à carreaux N/B.
2. Démagnétiser le tube extérieurement.
3. Mettre le TV en Mode Service 1.
4. Sélectionner le Mode Cutoff.
Pour régler le cutoff mettre un oscilloscope sur la cathode
"Bleu" et régler avec les touches "Jaune" et "Bleu" jusqu'a
ce que le niveau de noir soit à 160V±5V, mémoriser cette
valeur en appuyant sur "STR". Enlever l'oscilloscope et
sélectionner le réglage "Ug2" à l'écran et régler le
potentiometre "screen" du transfo THT pour que "OK" soit
indiqué à l'écran.