28
9 Measurements and Adjustments
9.1.
Adjustment
9.1.1.
Vsus selection
Caution:
When Plasma panel or A-board is replaced, Vsus should be set to LOW or HIGH.
Procedure
1. Go into main item [VSUS] in Service Mode. LOW or HIGH will be displayed.
2. Press [OK] button to go to TEST stage.
White pattern without On-Screen Display will be displayed during TEST and CONF stage. Press [5] button to display the
On-Screen Display.
3. Press [VOL (-)] button to set to LOW.
4. In LOW setting
a. If no several dead pixel is visible remarkably in white pattern, press [3] button to go to CONF stage.
b. If the several dead pixels are visible remarkably in white pattern, Set to HIGH by press [VOL (+)] button. Press [3] button
to go to CONF stage if the symptom is improved.
5. Press [OK] button in CONF stage to store LOW or HIGH.
6. Exit Service Mode by pressing [Power] button.
Summary of Contents for TXP42C2E
Page 21: ...21 7 4 No Picture ...
Page 32: ...32 ...
Page 38: ...38 ...
Page 40: ...40 11 4 Wiring 3 ...
Page 41: ...41 11 5 Wiring 4 ...
Page 42: ...42 ...
Page 43: ...43 12 Schematic Diagram 12 1 Schematic Diagram Note ...
Page 82: ...82 A B C D E F G H I 1 2 3 4 5 6 P BOARD COMPONENT SIDE LSEP1287LEHB ...
Page 92: ...92 ...
Page 94: ...94 14 1 2 Exploded View 2 ...
Page 95: ...95 14 1 3 Packing 1 ...
Page 96: ...96 14 1 4 Packing 2 ...
Page 97: ...97 14 1 5 Mechanical Replacement Parts List ...
Page 101: ...101 14 2 Electrical Replacement Parts List 14 2 1 Replacement Parts List Notes ...