9
ENGLISH
TO SET DAILY TIMER
TO SET DAILY TIMER
• To turn ON or OFF the unit at a preset time.
1
2
MODE
SELECT
Enter daily timer mode.
Select ON or OFF timer.
3
4
UP
DOWN
SET
Set the time.
Con
fi
rm.
• To cancel ON or OFF timer, press
CANCEL
.
• When ON timer is set, the unit may start early before
the actual set time in order to achieve the desired
temperature on time.
• Timer operation is based on the clock set in the remote
control and repeats daily once set. For clock setting,
please refer to Remote Control preparation.
• The timer closest to the current time will be activated
fi
rst.
• If timer is cancelled manually, you can restore the
previous setting by pressing
SET
.
• If the main power is switched off for an hour or more,
the clock and timer will need to be set again.
FAN
SPEED
TO SELECT FAN SPEED (3 OPTIONS)
LO
MED
AUTO
HI
• For AUTO, the indoor fan speed is automatically
adjusted according to the operation mode.
• If the operation mode is set to Fan, the fan speed will
be
fi
xed at MED regardless of the temperature setting.
AIR SWING
AUTO
MANUAL
TO ADJUST AIRFLOW
DIRECTION
• Keeps the room ventilated.
• The air is discharge evenly through 4 output vents.
AUTO
• The vertical air
fl
ow louver swings up and down
automatically.
• Do not adjust the vertical air
fl
ow direction louvers by
hand.
MANUAL
• There are 4 options for manual vertical air
fl
ow
direction.
• The air
fl
ow direction can be adjusted as desired by
using remote control.
HINT
HINT
• Use curtains to screen off sunlight and outdoor heat to
reduce power consumption during cool mode.
OFF / ON
TO TURN ON OR OFF THE UNIT
UP
DOWN
TO SET TEMPERATURE
• Selection range: 16°C ~ 31°C.
MODE
TO SELECT OPERATION MODE
AUTO mode - For your convenience
• Unit selects operation mode according to temperature
setting, outdoor and room temperature.
HEAT mode - To enjoy warm air
• Unit takes a while to warm up.
FAN mode - To enables air circulation in the room
COOL mode - To enjoy cool air
DRY mode - To dehumidify the environment
• Unit operates at low fan speed to give a gentle cooling
operation.
• During soft dry operation, the indoor fan operates at a
low fan speed.
• The louvers movement might not align with the remote
control display.
Summary of Contents for U-10EA1EU-10EA1E8
Page 86: ...86 I I Panasonic 86 87 88 89 90 91 92 94 95 96 97 H...
Page 87: ...87 E H Ni Cd ELCB Earth Leakage Circuit Breaker RCD Residual Current Device ELCB...
Page 88: ...88 C 32 43 21 5 27 24 16 15 5 C 21 C 80 2002 96 E 2006 66 E Pb...
Page 89: ...89 E B B A A stand by C C...
Page 96: ...96 FAN FAN OFF ON 60 DEFROST PRE HEAT...
Page 97: ...97 E TIMER OFF TIMER ON TIMER Auto OFF ON 15 8 C 14 C Heat 2 3...
Page 98: ...98 Panasonic 98 99 100 101 102 103 104 106 107 108 109...
Page 99: ...99 Ni Cd ELCB RCD ELCB...
Page 100: ...100 C 32 43 21 5 27 24 16 15 5 C 21 C 80 3 2002 96 EC 2006 66 EC Pb...
Page 101: ...101 A A B B C C...
Page 108: ...108 OFF ON 60 DEFROST PRE HEAT...
Page 109: ...109 OFF ON Auto OFF ON 15 8 C 14 C 2 3...
Page 110: ...MEMO MEMO...
Page 111: ...MEMO MEMO...