3WAY VRF SYSTEM Unit Specifi cations
4
- 10
8
7
6
5
4
3
2
1
1. Outdoor Unit
Unit Specifi cations (9)
MODEL NAME
3WAY SYSTEM Capacity Control Outdoor Unit <24-Ton>
GENERAL MODEL No.
WU-288MF1U9, WU-288MF1U9E
COMPONENT OUTDOOR UNIT
U-96MF1U9(E*)
U-96MF1U9(E*)
U-96MF1U9(E*)
SOURCE
208-230V/3N/60Hz
208-230V/3N/60Hz
208-230V/3N/60Hz
PERFORMANCE
Cooling capacity
BTU / h (kW)
288,000 (84.4)
Heating capacity
BTU / h (kW)
324,000 (94.9)
UNIT DIMENSIONS
Height
in. (mm)
82-9/16 (2097)
Width
in. (mm)
113 (2870)
Depth
in. (mm)
Ceiling dimension : 35 ~ +2-3/8
(890 ~ +60)
Net weight
lbs. (kg)
672 (305)
672 (305)
672 (305)
Color (Munsell code)
Silky shade (1Y 8.5 / 0.5)
ELECTRICAL RATINGS
Voltage rating
V
208
230
Cooling
Running amperes
A
69.5
64.7
Power input
kW
23.3
23.3
Power factor
%
92.8
90.2
Heating
Running amperes
A
76.2
71.0
Power input
kW
25.8
25.8
Power factor
%
94.0
91.2
Starting amperes
A
191
183
COMPRESSOR
Type - Q'ty
Inverter driven Rotary type x 1
+ Fixed Speed Scroll type x 1
Inverter driven Rotary type x 1
+ Fixed Speed Scroll type x 1
Inverter driven Rotary type x 1
+ Fixed Speed Scroll type x 1
Motor output
kW
2.7 + 3.75
2.7 + 3.75
2.7 + 3.75
Refrigeration oil
Type
FV68S (Ether oil)
Charge amount
gal
1.96 (7.4 liters)
1.96 (7.4 liters)
1.96 (7.4 liters)
Crankcase heater
W
25 + 32
25 + 32
25 + 32
Capacity control
%
–
Refrigerant amount at shipment
lbs. (kg)
R410A - 25.9 (11.8)
R410A - 25.9 (11.8)
R410A - 25.9 (11.8)
Refrigerant control
Electronic expansion valve
Defrost method
Reverse-cycle defrost, outdoor unit cycle defrost
Heat exchanger
Aluminum plate fin / Copper tube
FAN DEVICE
Type - Q'ty
Propeller fan x 1
Propeller fan x 1
Propeller fan x 1
Air circulation
CFM
5,650
5,650
5,650
External static pressure
in.WG
0
0
0
Motor output (No. of poles)
kW
0.7/8P
0.7/8P
0.7/8P
Protective devices
High pressure switch, overcurrent (CT method)
TUBING
Refrigerant tubing
Suction tube
in. (mm)
ø1-1/4 (ø31.75) (Brazing)
Discharge tube
in. (mm)
ø1-1/8 (ø28.58) (Brazing)
Liquid tube
in. (mm)
ø3/4 (ø19.05) (Brazing)
Balance tube
in. (mm)
ø3/8 (ø9.52) (Flare nut)
Drain port
–
External air temperature operation range
°F
Cooling: 14 ~ 113 °F (DB) Heating: -4 ~ 59 (WB)
Operation sound (Hi)
dB-A
58.0 (Quiet mode: 55.0)
Primary accessories
Connection tubing
ø1-1/8 (ø28.58) - ø3/4 (ø19.05)
ø7/8 (ø22.22) - ø3/4 (ø19.05)
ø3/4 (ø19.05) - ø5/8 (ø15.88)
Connection tubing
ø1-1/8 (ø28.58) - ø3/4 (ø19.05)
ø7/8 (ø22.22) - ø3/4 (ø19.05)
ø3/4 (ø19.05) - ø5/8 (ø15.88)
Connection tubing
ø1-1/8 (ø28.58) - ø3/4 (ø19.05)
ø7/8 (ø22.22) - ø3/4 (ø19.05)
ø3/4 (ø19.05) - ø5/8 (ø15.88)
* Outdoor unit model name ended with the letter “E”
Refer to the Section 1 “3. Salt-Air Damage Resistant Specifications.”
Rated conditions
Performance, electrical characteristics values and operating sound are based on JIS B8616 package A/C.
(Cooling : Indoor intake air temperature 80°F DB / 67°F WB. Outdoor intake air temperature 95°F DB.)
(Heating : Indoor intake air temperature 70°F DB. Outdoor intake air temperature 47°F DB / 43°F WB.)
TD831158-00̲3WAY̲VRF̲SYS.indb 10
TD831158-00̲3WAY̲VRF̲SYS.indb 10
2011/12/12 17:22:42
2011/12/12 17:22:42
Summary of Contents for U-72MF1U9
Page 118: ...Section 8 TENTATIVE ...