 About safety Remarks

1) Do not use these connectors beyond the specification sheets. 
The usage outside of specified rated current, dielectric strength, 
and environmental conditions and so on may cause circuitry 
damage via abnormal heating, smoke, and fire.
2) In order to avoid accidents, your thorough specification review 
is appreciated.
Please contact us if your usage is out of the specifications. 
Otherwise, Panasonic Corporation cannot guarantee the quality 
and reliability.
3) Panasonic Corporation is consistently striving to improve 
quality and reliability.
However, the fact remains that electrical components and 
devices generally cause failures at a given statistical probability. 
Furthermore, their durability varies with use environments or use 
conditions. In this respect, please check for actual electrical 
components and devices under actual conditions before use.
Continued usage in a state of degraded condition may cause the 
deteriorated insulation, thus result in abnormal heat, smoke or 
firing. Please carry out safety design and periodic maintenance 
including redundancy design, design for fire spread prevention, 
and design for malfunction prevention so that no accidents 
resulting in injury or death, fire accidents, or social damage will 
be caused as a result of failure of the products or ending life of 
the products.

 Cautions when using the product

Please use the product in accordance with the conditions 
described in these specifications.
The product quality cannot be warranted if the product fails 
because it is used outside the conditions in these specifications.
1) Cautions about the operating and storage environments
• Product failure due to condensation cannot be warranted.
• Use caution for avoiding dust.
• The following environment may deteriorate the product’s 
appearance and affect the product characteristics, and should 
thus be avoided.

• An environment in which the possible adherence of 
chemicals such as acid and alkali exists.
• In a gaseous atmosphere of salt, sulfide, etc.

2) This product has a structure requiring an insertion force for 
mating, but the mating may come off when an external force is 
applied to the plug, impact is applied by dropping, or vibration is 
applied in equipment. Sufficient caution should be used with the 
equipment to avoid such incidents.
3) The product cannot be used in a movable parts while the 
optical fiber is bent. Such use may cause deformation of the 
receptacle or breakage of the optical fiber.
4) In order to avoid a load on the plug and receptacle applied by 
the tensile force of the optical fiber, a redundant design is 
required with respect to the optical fiber length.

5) Use caution for wiring the optical fiber to avoid getting 
entangled or twisting. Also, use adhesive tape for securing the 
optical fiber for preventing excessive stress caused by vibration 
and impact.

6) Insertion and removal operations must be performed while the 
power is off.
Insertion or removal operations in a live condition (with current 
and voltage) may lead to a breakage.
7) Use caution with regard to the generation and handling of 
static electricity in the operating environment to protect the plug.
8) Secure sufficient insulation distance between the external 
metal enclosure of the plug and the peripheral components. The 
plug enclosure, which is connected to the ground, may give rise 
to danger from a short-circuit.
9) Mating of plug

• Mating direction
Mating of the plug and receptacle requires orientation. Align 
the receptacle shape in the direction of the optical fiber of 
plug.
• Mated condition
Make sure the plug is securely inserted into the receptacle.
After mating, a gap remains between the PC board and plug. 
Avoid applying excessive pressure.

10) Plug removal
For the removal operation, hold both sides of the metal 
enclosure and lift the plug upward.
* Do not pull the optical fiber and bushing.

11) Plug insertion
Because this product has been designed with a thin mating 
structure between the plug and receptacle for compact-sizing 
purposes, excessive tilting during insertion or removal leads to 
product fracture and separation of the solder section of 
terminals.
For avoiding breakage of the mating parts, confirm the alignment 
before mating.

12) When the product is used in a different environment and in 
accordance with a method other than described in this 
document, please consult us.

Bushing

Ex)

Optical fiber

Securing 
with tape

Insertion

Enclosure
metal side

Enclosure
metal side

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Downloaded from

Arrow.com.

Summary of Contents for V Series

Page 1: ... compact bi directional transmission device 4 Noise reduction and electrical isolation easily achieved APPLICATIONS Recommended for the following high speed device transmission or electrical isolation applications Electrical signal Differential signal Transmitter Receiver Optical signal Receptacle Plug E O conversion Optical fiber Electrical signal Differential signal E O Converter IC Laser diode ...

Page 2: ...n 1channel Transmission rate 0 02 6 Gbps 8b 10b coding Input output characteristic impedance 80 100 125 Ω Differential input voltage 200 1200 mV Input common mode voltage 150 340 mV Note 1 Input total jitter 0 24 UI Note 2 Input rise time 0 30 UI Input fall time 0 30 UI Differential output voltage 150 220 275 mV Note 2 Output common mode voltage 150 250 275 mV Note 2 Output rise time 0 50 UI Note ...

Page 3: ...7 18 19 20 Optical fiber side 1 2 3 4 5 6 7 8 9 10 Receptacle terminal No Terminal layout diagram Viewed from the top receptacle as transparent Receptacle No Name Wiring 1 Open No connection 2 GND 3 Differential output Differential output 4 Differential output Differential output 5 GND 6 Open No connection 7 Open No connection 8 Power Supply 3 3V DC 9 Power Supply 3 3V DC 10 GND 11 Open No connect...

Page 4: ... m 100 0 AYG4V1A065 L 12 7 9 1 0 60 0 40 5 9 3 9 External dimensions Lot No marking Note 1 Suction face 0 50 0 05 4 50 0 1 8 20 0 50 0 05 3 30 0 10 0 95 0 20 0 03 4 20 5 00 2 80 1 10 1 10 C 0 9 0 1 72 0 20 0 03 General tolerance 0 2 Note 1 The terminal close to the portion to be soldered have nickel barriers except nickel portions Mated height of plug and receptacle 6 5 Downloaded from Arrow com D...

Page 5: ...ordance with JIS C 0806 1990 However not applied to the mounting hole pitch of some connectors Specifications for the plastic reel In accordance with EIAJ ET 7200B 11 5 1 75 4 2 12 0 24 0 0 3 Leading direction after packaging 1 5 dia 0 1 0 25 4 1 Top cover tape Embossed carrier tape Embossed mounting hole Taping reel 380 dia Label Type Direction of tape progress Receptacle Downloaded from Arrow co...

Page 6: ...o the plug impact is applied by dropping or vibration is applied in equipment Sufficient caution should be used with the equipment to avoid such incidents 3 The product cannot be used in a movable parts while the optical fiber is bent Such use may cause deformation of the receptacle or breakage of the optical fiber 4 In order to avoid a load on the plug and receptacle applied by the tensile force ...

Page 7: ...than the ones above please refer to the latest product specifications 8 The temperature profiles given in this catalog are values measured when using the connector on a resin based PC board When performed reflow soldering on a metal board iron aluminum etc or a metal table to mount on a FPC make sure there is no deformation or discoloration of the connector before mounting 9 Consult us when using ...

Page 8: ...ng on the connector type the color of the connector may vary from connector to connector depending on when it is produced Some connectors may change color slightly if subjected to ultraviolet rays during storage This is normal and will not affect the operation of the connector 3 When storing the connectors with the PC boards assembled and components alreeady set be careful not to stack them up so ...

Reviews: