BEFORE PROGRAMMING
P-12
(01-04)11#-(0, 1-3)#
EXTERNAL RING OUTPUT
You can ring an incoming ringing tone from
an external speaker.
To set when (Day/Night) to ring.
0#: Does not ring
1#: Rings only in Day mode
2#: Rings only in Night mode
3#: Rings in both Day and Night mode
CP
(01-04)14#-(0, 1-7)#
INCOMING RING SIGNAL DETECTION TIME
Detects an incoming ring signal when the
signal is longer than the time programmed for
an incoming ring signal. For example, if the
time programmed of an incoming call signal is
200 mseconds or longer, signal that are longer
than 200 mseconds are identified as a phone
call. Any signal shorter than 200 mseconds are
not considered phone signal and are disre-
garded.
( 0 1 - 0 4 : Exchange
line N o . )
( 0 1 - 0 4 : Exchange
line N o . )
IMPORTANT
C
: The data copy is available for items with this mark.
P
: Power setting is required for items with this mark.
M
: Two or more setting can be assigned with this mark.
POWER SETTING using ON/OFF Switch:
There are four exceptions to programming from the administrator's telephone. The following
addresses can be only be programmed using the POWER SETTING:
MODE 1 - addresses:
0001# (EXCHANGE LINE)
0313# (SLT ON HOOK DETECTION TIMER)
0412# (SYSTEM SPEED DIAL)
0419# (OFF-HOOK MONITOR)
To change the data in the addresses above, perform the following steps:
1
Power ON
d
2
Enter data
d
3
Power OFF
d
4
Power ON
After POWER SETTING, the data has been changed.
Address No.
Data set range
■
PROGRAMMING OUTLINE
PROGRAMMING (MODE 2)
Function name
Data setting item
Data setting value
C
,
P
,
M
marks
Description
of function
Initial setting
item
Basic operation
Indicates the range of the Exchange line
No. (MODE 2), extension Style No. (MODE 3)
or extension No. (MODE 4-7)