P-40
PROGRAMMING (MODE 2)
(01-04: Exchange
line No.)
(01-04: Exchange
line No.)
(01-04: Exchange
line No.)
(01-04)20#-(1-3)#
M
END DETECTION OF INCOMING CALL
In case of incoming call, it is possible to automatically
release the Exchange line when the other party ends the
call.
To set how to detect the other party’s end.
None (No Detects)
1#: Detects by the polarity reverse signal
2#: Detects by Break signal
NOTE : • Two or more settings can be assigned.
• To delete the input data, press the same data
number again.
(01-04)21#-(0, 1 or 2)#
C
EXCHANGE LINE END DETECTION
MODE
This sets in which state the “END DETECTION OF
OUTGOING CALL (01-04)19#” and “END DETEC-
TION OF INCOMING CALL (01-04)20#” are detected.
0#: No detection
1#: Detection only while on HOLD
2#: Detection anytime
(01-04)22#-(0, 1-7)#
C
BREAK SIGNAL DETECTING TIMER (to
disconnect the Exchange line)
The signal detection time can be set within a range of 50
mseconds to 700 mseconds.
0#: More than 50 mseconds
1#: More than 100 mseconds
2#: More than 200 mseconds
3#: More than 300 mseconds
4#: More than 400 mseconds
5#: More than 500 mseconds
6#: More than 600 mseconds
7#: More than 700 mseconds
(01-04: Exchange
line No.)
8# : 8
9# : 9
10#: 10
11#: 11
12#: 12
13#: 13
14#: 14
15#: 15
8# : 4.5 seconds
9# : 5 seconds
10#: 5.5 seconds
11#: 6 seconds
12#: 6.5 seconds
13#: 7 seconds
14#: 7.5 seconds
(01-04: Exchange
line No.)
(01-04)23#-(1-3)#
ANSWER DETECTION OF OUTGOING
CALL
Sets how to detect the other party’s answer to an
outgoing call.
1#: Detection by timer
2#: Detection by polarity reverse signal
3#: Detection by timer and polarity reverse
signal
NOTE : The start time for an Exchange line call will be
defined by this detection. Printing to SMDR will be
done incorrectly unless the detection is correct.
REFERENCE : See MODE 1 0302#.
(01-04)24#-(0, 1-14)#
C
DT DETECTION TIME
Sets the detection time for DT detection. During DT
detection, the detection time preset here is counted to
detect the DT.
Set the detection time (0.5 to 7.5 seconds, 0.5 second
units).
0#: 0.5 seconds
1#: 1 second
2#: 1.5 seconds
3#: 2 seconds
4#: 2.5 seconds
5#: 3 seconds
6#: 3.5 seconds
7#: 4 seconds
(01-04)25#-(0, 1-15)#
C
DT DETECTION LOWER LIMIT COUNT
Sets the lower limit of the count for judging detection of
DT. If the DT detection count is larger than this lower
limit, this is judged as a DT.
Set how many times should be counted as the lower
limit.
0#: 0 (Continuous tone)
1#: 1
2#: 2
3#: 3
4#: 4
5#: 5
6#: 6
7#: 7