– 90 –
Chapter 10 Menu Operations — Menu list
Item
Description of settings
[USER7]
Sets the function to be assigned to the control panel operation button. The control panel operation button
functions as a USER button.
Assign [SIX BUTTONS] to USER buttons <1> to <4>.
[INHIBIT], [EXPAND], [ASSIST], [FRAME LINE], [VF COLOR], [MON1 COLOR], [MON2 COLOR],
[SMOOTH MODE]
f
Factory setting: [INHIBIT]
[USER8]
Sets the function to be assigned to the control panel operation button. The control panel operation button
functions as a USER button.
Assign [SIX BUTTONS] to USER buttons <1> to <4>.
[INHIBIT], [EXPAND], [ASSIST], [FRAME LINE], [VF COLOR], [MON1 COLOR], [MON2 COLOR],
[SMOOTH MODE]
f
Factory setting: [INHIBIT]
[USER9]
Sets the function to be assigned to the control panel operation button. The control panel operation button
functions as a USER button.
Assign [SIX BUTTONS] to USER buttons <1> to <4>.
[INHIBIT], [EXPAND], [ASSIST], [FRAME LINE], [VF COLOR], [MON1 COLOR], [MON2 COLOR],
[SMOOTH MODE]
f
Factory setting: [INHIBIT]
[USER10]
Sets the function to be assigned to the control panel operation button. The control panel operation button
functions as a USER button.
Assign [SIX BUTTONS] to USER buttons <1> to <4>.
[INHIBIT], [EXPAND], [ASSIST], [FRAME LINE], [VF COLOR], [MON1 COLOR], [MON2 COLOR],
[SMOOTH MODE]
f
Factory setting: [INHIBIT]
[BATTERY]
[BATTERY SELECT]
Selected according to the battery used.
[DIONIC], [HyTRON], [ENDURA], [PAG]:
The remaining charge level is detected and a warning is
displayed according to the [NEAR END Info] and [END Info] settings. When there is no remaining charge
level information, the remaining charge level is detected from the voltage level.
[other]:
Remaining charge level is detected from the voltage level.
f
Factory setting: [DIONIC]
[EXT DC IN SELECT]
Sets the type of the external power supply input into the <DC IN> terminal.
[DC POWER SUPPLY]:
Selected when connecting an AC adaptor. In this case, the remaining battery
charge level is not displayed.
[BATTERY]:
Selected when connecting a battery to the <DC IN> terminal. Remaining charge level is
detected from the voltage level.
f
Factory setting: [DC POWER SUPPLY]
[FULL Volt]
Sets the voltage in the remaining charge level full display when the battery remaining charge level is
detected from the voltage level.
[13.0V] - [17.0V]
(0.1 V step)
f
Factory setting: [15.5V]
[NEAR END Volt]
Sets the remaining charge level near end voltage when the battery remaining charge level is detected from
the voltage level.
[11.0V] - [15.0V]
(0.1 V step)
f
The maximum value is the value set in [FULL Volt]. (However, the maximum is [15.0V])
f
Factory setting: [13.2V]
[END Volt]
Sets the remaining charge level end voltage when the battery remaining charge level is detected from the
voltage level.
[11.0V] - [15.0V]
(0.1 V step)
f
The maximum value is the value set in [NEAR END Volt].
f
Factory setting: [12.5V]
[NEAR END Info]
Sets the percentage value of the remaining charge level near end when remaining charge level information
is acquired from the battery.
[4%], [5%], [6%], [7%], [8%], [9%], [10%], [12%], [14%], [16%], [18%], [20%]
f
Factory setting: [5%]
[END Info]
Sets the percentage value of the remaining charge level end when remaining charge level information is
acquired from the battery.
[1%] - [10%]
(1% step)
f
The maximum value is the value set in [NEAR END Info]. (However, the maximum is [10%])
f
Factory setting: [1%]
[EXT DC FULL]
Sets the voltage to be displayed in the remaining charge level full display when an external power supply
is input from the <DC IN>.
[13.0V] - [17.0V]
(0.1 V step)
f
Factory setting: [15.5V]
[EXT DC NEAR END]
Sets the remaining charge level near end voltage when an external power supply is input from the <DC
IN>.
[11.0V] - [15.0V]
(0.1 V step)
f
The maximum value is the value set in [EXT DC FULL]. (However, the maximum is [15.0V])
f
Factory setting: [13.2V]
[EXT DC END]
Sets the remaining charge level end voltage when an external power supply is input from the <DC IN>.
[11.0V] - [15.0V]
(0.1 V step)
f
The maximum value is the value set in [EXT DC NEAR END].
f
Factory setting: [12.5V]
[END ALARM]
Sets whether to sound an alarm at battery remaining charge level end.
[ON], [OFF]
f
Factory setting: [ON]
Summary of Contents for Vericam 35
Page 1: ...35 Operating Guide W1014HM0 YI VQT5K88A E ...
Page 5: ...Before using the camera read this chapter Chapter 1 Overview ...
Page 65: ...This chapter describes video output Chapter 8 Output and Screen Display ...
Page 113: ...This chapter describes the specifications of this product Chapter 12 Specification ...
Page 118: ...Index 118 Z Zebra patterns 63 ...