4. Disconnect the connector (S2).
5. Remove the Power Button.
6. Remove the screw (
×
1
) and remove the S-Board.
7.19. Remove the K-Board
1. Remove the Cabinet assy. (See section 7.17.)
2. Remove the S-Board. (See section 7.18.)
3. Remove the screws (
×
5 ).
4. Remove the Glass holder bottom rear.
5. Remove the screws (
×
4 ).
6. Remove the Glass holder side (L, R).
7. Remove the screws (
×
7 ).
8. Remove the Glass holder top rear and the Glass holder
top front.
9. Remove the Glass holder bottom front.
10. Remove the screw (
×
1 ).
11. Remove the claw (
×
1 ).
12. Disconnect the connector (K1) and Remove the K-Board
from LED Panel.
7.20. Replace the plasma panel
1. Place the new plasma panel on the flat surface of the
table (covered by a soft cloth), with the plasma panel sur-
face facing downward.
2. Attach the C1-Board and the C2-Board, connect the flexi-
ble cables (
×
8) from the plasma panel to the C1-Board
and the C2-Board, and fit the flexible cable holders.
3. Attach the Hooks (left, right) and fit the Stand brackets (L,
R) to the new plasma panel.
4. Place the plasma panel section on the servicing stand.
5. Attach the cabinet assy and each P.C.Board and so on, to
the new plasma panel.
*When fitting the cabinet assy, be careful not to allow
any debris, dust or handling residue to remain
between the front glass and plasma panel.
Summary of Contents for Viera TC-P42X1
Page 15: ...15 6 4 No Picture ...
Page 25: ...25 8 1 4 Adjustment Volume Location 8 1 5 Test Point Location ...
Page 27: ...27 ...
Page 28: ...28 ...
Page 34: ...34 10 3 Wiring 2 ...
Page 35: ...35 10 4 Wiring 3 ...
Page 36: ...36 10 5 Wiring 4 ...
Page 37: ...37 11 Schematic Diagram 11 1 Schematic Diagram Note ...
Page 68: ...68 A B C D E F G H I 1 2 3 4 5 6 P BOARD COMPONENT SIDE LSEP1279ANHB ...
Page 80: ...80 ...
Page 82: ...82 13 1 2 Accessories ...
Page 83: ...83 13 1 3 Mechanical Replacement Parts List ...
Page 86: ...86 13 2 Electrical Replacement Parts List 13 2 1 Replacement Parts List Notes ...