26
8.16. Remove the Glass holders
1. Remove the Cabinet assy. (See section 8.15.)
2. Remove the screws (
×
4 ).
3. Remove the Glass holder side (L, R).
4. Remove the screws (
×
9 ).
5. Remove the Glass holder top.
6. Remove the screws (
×
7 ).
7. Remove the Glass holder bottom.
8.17. Remove the K-Board
1. Remove the Glass holders. (See section 8.16.)
2. Remove the screw (
×
1 ).
3. Remove the claws (
×
2 ).
4. Disconnect the connector (K1) and Remove the K-Board
from LED Panel.
8.18. Replace the plasma panel
Caution:
A new plasma panel itself without Hanger metals is
fragile.
To avoid the damage to new plasma panel, carry a new
plasma panel taking hold of the Hanger metals after
assembling the Hanger metals and the Stand brackets.
1. Place a carton box packed a new plasma panel on the flat
surface of the work bench.
2. Open a box and without taking a new plasma panel;
Attach the C1-Board and the C2-Board, connect the flexi-
ble cables from the plasma panel to the C1-Board and the
C2-Board, and fit the flexible cable holders.
3. Attach the Hanger metals and the Stand brackets to the
new plasma panel.
4. Place the plasma panel on the servicing stand taking hold
of the Hanger metals.
5. Attach the cabinet assy and each P.C.Board and so on, to
the new plasma panel.
*When fitting the cabinet assy, be careful not to allow any
debris, dust or handling residue to remain between the
front glass and plasma panel.
Summary of Contents for Viera TC-P50X20P
Page 19: ...19 6 4 No Picture ...
Page 36: ...36 ...
Page 38: ...38 11 3 Wiring 2 11 4 Wiring 3 ...
Page 39: ...39 11 5 Wiring 4 ...
Page 40: ...40 ...
Page 41: ...41 12 Schematic Diagram 12 1 Schematic Diagram Note ...
Page 78: ...78 ...
Page 80: ...80 14 1 2 Exploded View 2 ...
Page 81: ...81 14 1 3 Packing 1 ...
Page 82: ...82 14 1 4 Packing 2 ...
Page 83: ...83 14 1 5 Mechanical Replacement Parts List ...
Page 86: ...86 14 2 Electrical Replacement Parts List 14 2 1 Replacement Parts List Notes ...