background image

Installation Guide

Video Intercom System — Power Supply Unit

Model No.    

VL-PS240

Thank you for purchasing a Panasonic product.
Please follow all instructions in this document and save it for future reference.
Carefully read the information found in the section titled "1.1  Important safety information" in particular.

This product is a separately sold power supply unit for use with Panasonic Video Intercom Systems.

Note to the installer

R

Please read this document carefully, and install the product safely and correctly by following the
instructions.

R

Only use attachments/accessories specified by the manufacturer.

R

The installation shall be carried out in accordance with all applicable installation rules.

Summary of Contents for VL-PS240

Page 1: ...ction titled 1 1 Important safety information in particular This product is a separately sold power supply unit for use with Panasonic Video Intercom Systems Note to the installer R Please read this document carefully and install the product safely and correctly by following the instructions R Only use attachments accessories specified by the manufacturer R The installation shall be carried out in...

Page 2: ...rtant information 4 1 5 General information 4 1 6 For India only 5 1 7 For Europe 5 2 Preparation 2 1 Included items 6 2 2 Specifications 6 2 3 Device diagrams 6 3 Installation 3 1 Installation cautions 7 3 2 Installing the power supply unit 7 3 3 Cleaning 10 3 4 Terms and illustrations in this document 10 2 Table of Contents ...

Page 3: ... connections when the power outlet is turned on R Do not install the product and power supply unit in the following places Places where the product and power supply unit may be splashed with water or chemicals Places where there is a high concentration of dust or high humidity R Do not push any objects through the openings of the product R If any of the following conditions occur disconnect the po...

Page 4: ...you stop using the product remove it from the walls to prevent it from falling off R When power fails this product cannot be used R Panasonic may not be liable for damages due to external factors such as power failures 1 5 General information R In the event of problems you should contact your equipment supplier in the first instance R After removing the product and any included items from the pack...

Page 5: ...dia only Declaration of Conformity with the requirements of the E Waste Management Rules The Product is in conformity with the requirements of the reduction of hazardous substances of the E Waste Rules The content of hazardous substance with the exemption of the applications listed in SCHEDULE II of the E Waste Rules 1 Lead Pb not over 0 1 by weight 2 Cadmium Cd not over 0 01 by weight 3 Mercury H...

Page 6: ...6 A Dimensions mm height width depth excluding protruding sections Approx 116 100 54 Mass weight Approx 230 g Operating environment Ambient temperature approx 0 C to 50 C Relative humidity non condensing up to 90 Installation method Attach to DIN rail Wall mount using included screws External material Flame retardant PC ABS resin 2 3 Device diagrams Example power supply unit with the cable cover r...

Page 7: ...ing off the wall Avoid installing onto low strength walls such as gypsum board ALC autoclaved lightweight concrete concrete block or veneer less than 18 mm thick walls 3 2 Installing the power supply unit Required items Power supply unit Cable binders included with power supply unit Screws included with power supply unit Wires for AC and DC connection user supplied See 3 2 4 Wire type and maximum ...

Page 8: ... DC wire and which terminal each wire should be connected to and insert the DC wires as shown CAUTION R Insert the power cables firmly all the way into the terminals If the cables are not inserted all the way heat may be generated 4 Tighten the terminal screws to secure the AC and DC wires bare wire area to the terminals and then use the cable binders to secure the AC and DC wires jacketed area to...

Page 9: ...and maximum wire length Wiring run Wire diameter Max length Power supply unit Connected device example lobby station distributor main monitor etc 0 65 mm 22 AWG approx 10 m 1 2 mm 12 AWG approx 20 m 1 Power supply unit AC power source 1 2 mm 17 AWG No requirement 2 mm 12 AWG 1 The maximum wiring length differs depending on the connected device For details refer to the documentation included with t...

Page 10: ...x petroleum or boiling water Also do not spray the product with insecticide glass cleaner or hair spray This may cause a change in colour or quality of the product 3 4 Terms and illustrations in this document R Model number suffixes e g the BX in VL PS240BX are omitted unless necessary R Design and specifications are subject to change without notice R Illustrations may vary slightly from the actua...

Page 11: ...11 Notes ...

Page 12: ... Panasonic Corporation 2018 1006 Oaza Kadoma Kadoma shi Osaka 571 8501 Japan http www panasonic com PNQP1423ZA C0618MG0 ...