E-55
SYSTEM menu
SYSTEM menu
Items
Setting
Contents
STILL MODE
SERIES REC
TIME
STILL TIMER
PAUSE
PROTECT
INDEX WRITE
DC IN MODE
PAGE BACK
FIELD
1st
2nd
FRAME
OFF
25MIN
55MIN
75MIN
115MIN
175MIN
265MIN
30SEC
1MIN
2MIN
3MIN
5MIN
F.ADV
STBY-OFF
OFF
ON
POWER OFF
POWER ON
PLAY
Use this item to select the still image type during the STILL mode or frame
advance playback:
FIELD
: Displays field image. During frame advance playback, 1st and
2nd field images are displayed alternately.
1st
: displays the 1st field image.
2nd
: displays the 2nd field image.
FRAME
: displays the frame image.
Memo
The image type for the STILL mode can also be selected with the STILL
MODE button on the wireless remote controller.
Set this item according to the recording time of the source tape during DV
signal input series recording:
OFF
: No series recording.
25MIN
: Use this setting if the recording time of the source tape is 30
mins.
55MIN
: Use this setting if the recording time of the source tape is 60
mins.
75MIN
: Use this setting if the recording time of the source tape is 80
mins.
115MIN
: Use this setting if the recording time of the source tape is 120
mins.
175MIN
: Use this setting if the recording time of the source tape is 180
mins.
265MIN
: Use this setting if the recording time of the source tape is 270
mins.
(
☞
Page 38 “Series recording function”)
Sets the interval after the lapse of which the tape protection mode will be
engaged during an extended STILL mode. The setting for the STILL mode
can be done via the PAUSE PROTECT menu item.
30SEC: 30 seconds
1MIN
: 1 minute
3MIN
: 3 minutes
2MIN
: 2 minutes
5MIN
: 5 minutes
Memo
To prevent damage, please set as short a time interval as possible.
Sets the action to be taken when the unit has been left in the STILL mode for
an extended period of time. In the case of a recording pause, the unit will go
into the STOP state to protect the tape, regardless of the setting.
F.ADV
: It advances in the forward direction. On the 6th advancement,
it goes into the STOP state.
STBY-OFF : Goes into the STOP state.
Selects whether to record the index signals during recording which is en-
gaged after the STOP or recording PAUSE mode.
OFF
: No recording of index signal.
ON
: Use this setting to record index signals. An index signal is automati-
cally registered at the position where recording starts.
Select the action to perform when power is supplied via the DC IN terminal:
POWER OFF : Sets the unit to POWER OFF.
POWER ON
: Sets the unit to POWER ON.
PLAY
: If a tape has been inserted, the VTR will go
into the PLAY mode. (AUTO PLAY)
Return to the top MENU
Summary of Contents for VQT0C55
Page 68: ......