Always disconnect the power source before working on or near the fan, motor or junction box.

Protect the supply wiring from sharp edges, oil, grease, hot surfaces, 
chemicals or other objects. 

Do not kink the supply wiring.

Not for use in cooking area. (Fig. A)

The special-purpose or dedicated parts, such as mounting fixtures, 
must be used if such parts are provided. 

For general ventilating use only. Do not use to exhaust hazardous or 
explosive materials and vapors.

Floor

45

°

45°

Cooking

equipment

Fig. A

(Cooking area)

Do not install above or

inside this area

Provide make up air for proper ventilation.

Do not connect multiple units in parallel. If two or more units are connected to one switch in parallel, the units 
may not function. 

Do not install the unit where ducts are configured as shown in below:

Bend close to duct adaptor

Squeezed duct

Successive bending

Excessive bending

Adaptor

These products use a sirocco fan driven by a DC motor powered by an integral transformer. The motor is designed to
have long operating life, high dynamic response, higher speed ranges and energy savings. The grille covering the fan 
body is a spring-attached, quick removal type. A damper for preventing air counter flow is provided. The blower uses
a high-capacity sirocco fan developed to reduce the noise level. The lighting unit is an energy-saving LED lighting 
device that uses one 10 W LED lamp and produces almost the same illumination as a standard 40 W incandescent 
lamp. Night light feature consumes around 0.1 to 0.4 W.       

These products are listed by UL under UL file No. E78414.

FCC Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant 

to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference 

in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed 

and used in accordance with the instructions, may cause harmful interference to radio communications. However, 

there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful 

interference to radio or television reception, which can be determined by turning this product on and off, the user is 

encouraged to try to correct the interference by one of the following measures:      

 SDoC Responsible Party:

                                                   Two Riverfront Plaza, Newark, NJ 07102

               1-866-292-7299

Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.

Consult the dealer or an experienced radio/TV technician for help.

Panasonic Corporation of North America

Connect equipment into outlet on a circuit different from that to which the receiver is connected. 

Warning: This equipment must be installed by a qualified person in accordance with the provided installation

instructions and all applicable codes and standards. Also, any changes or modifications not expressly approved by

the party responsible for compliance could void the user’s authority to operate this equipment.

 Customer Call Center:

3

GENERAL SAFETY INFORMATION (CONTINUED)

DESCRIPTION

Summary of Contents for WhisperRemodel RG-R811LA

Page 1: ... of life electric shock fire malfunction and damage to equipment or property always observe the following safety precautions WARNING CAUTION Denotes a potential hazard that could result in serious injury or death Denotes a hazard that could result in minor injury Denotes a hazard that could result in property damage The following symbols are used to classify and describe the type of instructions t...

Page 2: ... the flue chimney of fuel Ducted exhaust fans must always be vented to the outdoors If this unit is to be installed over a tub or shower it must be marked as appropriate for the application and connected to a GFCI Ground Fault Circuit Interrupter protected branch circuit These models are UL listed for tub and shower enclosures This product is not to be installed in a ceiling thermally insulated to...

Page 3: ...ight light feature consumes around 0 1 to 0 4 W These products are listed by UL under UL file No E78414 FCC Note This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and ca...

Page 4: ...st to verify that all parts are present 1 Grille Self drilling screw Installation instructions Warranty sheet Machine screw M4X8 3 inch duct reducer optional part Unit inches mm 4 DESCRIPTION CONTINUED DIMENSIONS SUPPLIED ACCESORIES UNPACKING 5 5 8 140 12 1 8 307 4 3 7 8 96 7 11 1 3 7 6 5 2 13 330 5 5 8 143 10 9 10 3 4 271 2 3 4 69 7 2 7 8 71 4 1 3 8 32 6 1 1 2 37 8 13 330 10 3 8 263 5 1 4 133 Par...

Page 5: ...e built using DC motor technology The DC motor is 30 70 more energy efficient than the minimum ENERGY STAR requirements Air volume option CFM 80 110 80 CFM Factory setting Pick A Flow Feature This product comes with Pick A Flow speed options The Pick A Flow switch on the face of the product allows the option to choose 80 or 110 CFM This product can run continuously or intermittently depending upon...

Page 6: ...to the opening and extend Align and install bracket to joist by using 2 preinstalled tapping screws Joist 5 2 Tapping screws ST4 2X20 Extend 4 Install circular exhaust duct 2 1 Remove screw from junction box cover to remove the knock out hole and secure conduit or stress relief to junction box knock out hole Install the circular exhaust duct and secure it with clamps or ties and seal it with masti...

Page 7: ...ode NEC Use UL approved wire nuts to connect fan wires After connecting wires replace junction box cover Install adaptor 1 2 Self drilling screws Circular exhaust duct Conduit 1 Self drilling screw Drywall Joist Joist Drywall 1 Install the adaptor to Flex Z Fast bracket by using 2 self drilling screws Insert fan body Insert fan body and slide into adaptor assembly using the guide parts until you h...

Page 8: ...oes not strip or come in contact with the Flex Z Fast bracket Insert the mounting springs into the slot as shown to mount grille to fan body 2 Connect the LED lamp wire to receptacle 1 Install grille CAUTION IMPORTANT Remove the tape placed on the damper and adaptor before installation Failure to do so will cause the product to work inefficiently and create a loud noise If you require use of the 3...

Page 9: ...or approved foil tape A 3 or 4 inch circular duct is needed to connect to the relevant part of the adaptor Install the adaptor to Flex Z Fast bracket by using 2 self drilling screws Connect wires Black White Green Wire nuts Switch Blue Live Light Neutral Conduit Live Fan Neutral Live Night Light Earth ground L N AC 120 V 60 Hz Power supply Earth ground Switch box Refer to WIRING DIAGRAM Page 5 Fol...

Page 10: ...ther such chemicals for cleaning the ventilating fan Remove grille 1 2 1 Gloves Slot Grille Mounting spring Remove grille by pulling down one mounting spring Disconnect the wire from the receptacle then pull down the other mountain spring 1 2 Plug connector into receptacle and secure fan body to adaptor by using the machine screw M4X8 When the flange overlaps Flex Z Fast bracket secure it by using...

Page 11: ... subjected to these limitations The ducting from this fan to the outside of the building has a strong effect on the air flow noise and energy use of the fan Use the shortest straightest duct routing possible for best performance and avoid installing the fan with smaller ducts than recommended Insulation around the ducts can reduce energy loss and inhibit mold growth Fans installed with existing du...

Page 12: ...n how long an implied warranty lasts so the above exclusions or limitation may not apply to you Obtain Product Information and Operating Assistance locate your nearest distributor or make Customer Service and Literature requests by visiting our Web Site at us panasonic com ventfans or send your request by E mail to ventfans us panasonic com You may also contact us directly at 1 866 292 7299 Monday...

Reviews: