Security Intercom Model 3M Call Sub-base Unit with Monitor
(Recessed Type) (White)
Security Intercom Model 3M Call Sub-base Unit
(Recessed Type) (White)
警報音停止
STOP ALARM
電源
POWER
Part Names and Functions
Unit expansion adapter (sold separately) on the base unit is
required to use.
Note
●
Unit expansion adapter (sold separately) on the base unit is
required to use.
●
There is no function other than talk, alarm, and call.
Note
VOLUME
EXTENSION
UNLOCK
TALK
呼出音量
室内呼
解錠
通話
EMERG.
非常
VGD13113W
VGD13113W
ALARM
LOBBY
警報
ロビー
ALARM
LOBBY
警報
ロビー
MANAGER
管理
MANAGER
管理
Product
number
Adjustment of the ringtones
volume setting is performed
in the user setting.
( Page 101)
Speaker
LCD monitor
EMERGENCY button
OFF button
TALK button
STOP ALARM button
Microphone for talking
MENU button
( Pages 58 to 60, 155)
An alarm will sound and
flashes in red when pressed.
The alarm will stop sounding
and turn off when pressed
again.
The alarm will stop
sounding when pressed.
The alarm sounding on the
base unit and the call
sub-base unit will also stop.
Fire and gas leak alarms
can only be stopped on
the base unit.
Press to enter into the Top
Menu screen. The area
around the button will flash
in blue when there is
notification for a visitor or
delivery when you were not
home, and will flash in red
when there is an alarm.
Press to enter the waiting
state (nothing is displayed
on the screen). This also
can end the talk.
Press to talk or to end
talking.
It will flash in red when
calling, and illuminate in
red when talking.
Note
This is the touch panel type
LCD monitor.
Do not use generic LCD
protection film.
The touch panel may not
work properly.
Note
This indicates that the power
is turned on by illuminating in
green.
POWER indicator
UNLOCK button
The electronic lock is unlocked
when pressed while talking to main
entrance or unit entrance. It will flash
in green if unlocking is possible.
The unit entrance can be
locked, and it will flash in
green if locking is possible.
The electronic lock lock/unlock
of the unit entrance can be
used when the electronic lock
system of the unit is installed
linked to the condominium HA
system.
Note
16
17
Item number
VGD13111W
電源
POWER
●
This is not displayed in normal conditions.
●
Installation setting on the base unit is necessary to display the Unlock indicator.
(Consult with the management company or the company that installed the system.
Item number
VGD13113W
Press to talk or to end talking.
It will flash when calling, and light up in red when talking.
(The color for lighting up or flashing differs depending on
the call destination or talk destination.)
●
Main entrance and building manager room: Red
●
Unit entrance: Yellow
●
Internal call: Green
TALK button
Item number
Speaker
●
Volume cannot be adjusted on the talk volume and
alarm volume.
●
The call from the base unit or other call sub-base unit
will sound in "Low" even if it is set as "Off".
VOLUME button
EXTENSION button
Calls the base unit or other
call sub-base unit when
pressed.
The call volume is switched
between 3 levels (Low
→
Medium
→
High
→
Off)
every time it is pressed. (Setting at shipment: Medium)
UNLOCK button
Microphone for talking
EMERGENCY button
Call sound off indicator
Unlock indicator
MANAGER indicator
ALARM indicator
This will flash in red
when an alarm is generated.
LOBBY indicator
This will illuminate in red when there is a call
from the main entrance.
This will illuminate in red when there is a call
from the building manager room.
This will illuminate in red when the electronic
lock of the unit entrance is unlocked, and
turns off when locked.
●
This is not displayed in normal conditions.
●
Installation setting on the base unit is necessary to display the Unlock indicator.
(Consult with the management company or the company that installed the system.)
This will light up in red when the electronic lock of
the unit entrance is unlocked, and turn off when locked.
Unlock indicator
Call sound off indicator
This will light up in red when volume
setting is set to "Ringtones Volume
settings: Off" on the call sub-base
unit with monitor or volume setting is
set to "ringtones volume settings:
Off" on the base unit. ( Page 101)
This will illuminate in red
when the VOLUME button
(described below) is set to
"Off" or when volume setting
is set to "ringtones volume
settings: Off" on the base
unit.
An alarm will sound and the
button will flash in red when
pressed. The alarm will stop
sounding and turn off when
pressed again.
The electronic lock is unlocked
when pressed while talking to
the main entrance or unit
entrance. It will flash in green if
unlocking is possible.
The unit entrance can be
locked, and it will flash in
green if locking is possible.
The electronic lock lock/unlock
of the unit entrance can be
used when the electronic lock
system of the unit is installed
linked to the condominium HA
system.
INTRODUCTION
USUAL USAGE
SETTING ACCORDING TO
YOUR PREFERENCES
OPERATIONS AND MEASURES
WHEN ALARM GOES OFF
SECURITY ALARM SETTING
AND DISARMING
RECORD
MANAGEMENT
OTHER
Note
Note
Note
Note