The screen display does not turn off while
electricity usage is 110% or higher.
●
The on-screen icon can also be turned off
within 1 minute. ( Page 155)
●
The Alarm 1 icon will turn off after approximately
3 minutes, and the area around the MENU button
will flash in red.
●
The alarm stops once reset. Also, the area around the
MENU button, the call sub-base unit alarm indicator,
and door phone alarm display indicator turn off.
●
The on-screen icon can also be turned off within
3 minutes. ( Page 155)
●
Up to 4 general use alarms can be connected.
The screen display appears in accordance with
the configured installation settings.
When Electricity is Overused
174
175
STOP ALARM button
Power Consumption
"Limiter ON"
setting
100%-110%
90%-110%
110%-120%
110%-120%
120% and over
120% and over
Once every 3 minutes
Once every 10 seconds
Once every 5 seconds
Once every 3 minutes
Once every 10 seconds
Once every 5 seconds
100%-110%
90%-110%
110%-120%
110%-120%
120% and over
120% and over
-
"Limiter Off"
setting
Message
display
Too much
electricity is
being used.
Electricity
usage indicator
"Limiter ON"
setting
"Limiter Off"
setting
Message
display
Electricity
usage indicator
Screen display
Alarm interval
Alarm
message
■
Using a data output distribution panel with a 5-level display
Power consumption
Screen display
Alarm interval
Alarm
message
■
Using a photocoupler output distribution panel without a level meter
●
Reduce your power consumption.
Electricity usage
indicator flashes
in white
Message display
appears in white
●
Press the STOP ALARM button.
How to stop the alarm message
Procedures for message displays
●
This screen appears when using a distribution panel with over-currency alarm.
●
Confirm that system components are properly installed before using the system.
●
The LCD icon will turn off after approximately
1 minute, and the area around the MENU button
will flash in red.
●
The alarm message stops once electricity usage
is below 100% or below 90%.
LCD Displays and Alarm Messages
(Beeps) Too much electricity
is being used.
When General Use Alarms Are Triggered
Door phone
Alarm display indicator
Flashes in red
Alarm is sounding
Call sub-base unit
ALARM indicator
Flashes in red
Alarm is sounding
Alarm 1 icon flashes
in red
●
Press the STOP ALARM button.
(The alarm can also be turned off from the building
manager room.)
How to stop the alarm sound
MENU button
Confirm that system components are properly installed before using the system.
●
See page 175 for more information on
LCD displays and alarm messages.
The system reports that electricity is being overused when such scenarios occur.
The alarm message will stop for a moment but
will then continue to sound until the power
consumption is less than either below 100% or
below 90%.
The distribution panel settings must
be changed to change the
contracted electricity demand.
Consult with the management
company or the company that
installed the system.
Message display
appears in red
●
Display on the base unit when
using a residence distribution
board with over-currency
alarm (data output type)
Distribution panels have "limiter ON/OFF" settings. The data output type of distribution panel has "5-stage
display type", and the photocoupler type of distribution panel has "no level display type". The level of electricity
measured by the distribution panel varies depending on the settings and type of distribution panel. Check
which type of distribution panel you have and refer to its operation manual.
Too much
electricity is
being used.
3 flashing green
icons, 1 flashing
yellow icon, and
1 flashing
orange icon
(Beeps) Too
much electricity
is being used.
(Beeps) Too
much electricity
is being used.
Note
Note
Note
Note
Note
Note
Note
Note
INTRODUCTION
USUAL USAGE
SETTING ACCORDING TO
YOUR PREFERENCES
OPERATIONS AND MEASURES
WHEN ALARM GOES OFF
SECURITY ALARM SETTING
AND DISARMING
RECORD
MANAGEMENT
OTHER
Installer
Setting
Call sub-base unit
ALARM indicator
flashes in red
Alarm is sounding
MENU button
does not appear in the call sub-base
unit with monitor.
●
For base unit
When the general use alarm is triggered, the system reports this event with an alarm display.
STOP ALARM button
(Siren)
●
does not appear in the call sub-base
unit with monitor.
●
The following message appears in the
display when using a distribution panel
without a level meter.