The message volume can be adjusted.
( Page 120)
●
The error report message turns off approximately
1 minute after receiving the error report signal.
STOP ALARM button
Earthquake
Information icon
appears in white
178
179
If incorrect information is received, the system reports the event with a screen display and sound.
If test information is received, the system reports the event with a screen display and sound.
How to stop error messages
●
Press the STOP ALARM button.
How to stop test messages
●
The earthquake (test) display turns off when
the test message stops.
●
Press the STOP ALARM button.
If the Earthquake Early Warning System (prediction) information
was incorrect
Testing the Earthquake Early Warning System (prediction) from
the Building Manager Room
STOP ALARM
button
Incorrect error
message appears
in white
(Beep) The earthquake alarm from
a moment ago was an error.
Please be at ease.
Earthquake
display flashes
in red
Call sub-base unit
Emergency earthquake
alert (error) is
occurring
Call sub-base unit
Emergency earthquake
alert (test) is
sounding
In the Event of an Earthquake
Using the Simplified Earthquake Intensity Display
*1
How to stop the earthquake alert (prediction)
message
●
Press the STOP ALARM button.
●
The message volume can be adjusted.
( Page 120)
When an Earthquake is Expected
STOP ALARM button
If earthquake alarm (prediction) information is received, the system reports the event with
screen displays and sounds.
(Siren) Warning! An earthquake
is about to come.
Using the Detailed Earthquake Intensity Display
Intensity 3 to 5-lower
Intensity 5-lower or above
Consult with the management
company or the company that
installed the system.
●
The incorrect information screen does not
appear when the S-wave sensor incorrectly
detects an earthquake.
●
The call sub-base unit with monitor plays
the alert at the volume configured with the
base unit. The volume of the call sub-base
unit cannot be adjusted. The volume
corresponds with the "High" setting.
(Beep) We are now beginning an earthquake alarm
test. (Siren) Warning! An earthquake is about to
come. Intensity of 6 (six)-lower, (siren), ....(beep)
The earthquake alarm test is now over.
The test message on the right appears when
the test is started 30 seconds beforehand. The
test pattern varies depending on the settings of
the Earthquake Early Warning System interface
panel.
The system can be configured to stop the earthquake
alert (prediction) message automatically and to turn off
the earthquake alert after a specified amount of time
(can be less than 1 minute) after the building starts
shaking.
●
The call sub-base unit with monitor plays
the alert at the volume configured with the
base unit. The volume of the call sub-base
unit cannot be adjusted. The volume
corresponds with the "High" setting.
●
Nothing appears for earthquakes predicted
to have an intensity of 2 or less.
The earthquake alert (prediction)
message can be played from the
door phone when an earthquake with
an intensity of 5-lower or above is
predicted.
Call sub-base unit
Emergency earthquake
alert (prediction) is
sounding
Call sub-base unit
Emergency earthquake
alert (prediction) is
sounding
Earthquake
icon (intensity
of 3 to 5-lower)
appears in
yellow
Intensity 5-lower
or above icon
flashes in red
Note
Note
Note
INTRODUCTION
USUAL USAGE
SETTING ACCORDING TO
YOUR PREFERENCES
OPERATIONS AND MEASURES
WHEN ALARM GOES OFF
SECURITY ALARM SETTING
AND DISARMING
RECORD
MANAGEMENT
OTHER
●
The earthquake alert (prediction) message
stops automatically, and the earthquake icon
turns off after approximately 1 minute ( ).
Earthquake (test)
icon flashes in red
●
For base unit
●
For base unit
STOP ALARM button
*1
(Siren) Warning! A strong
earthquake is about to come.
●
For base unit
●
For base unit
Installer