34
■
LIVE VIDEO
Set the transmission rate of live images from cameras.
The following are available for the transmission rate.
OFF/0.1 ips/0.2 ips/0.3 ips/0.5 ips/1 ips/2 ips/3 ips/
5 ips/10 ips/15 ips
■
Manual REC Operation
Perform the recording rate for manual recording.
The following are available for "Recording Rate".
OFF/0.1 ips/0.2 ips/0.3 ips/0.5 ips/1 ips/2 ips/3 ips/
5 ips/10 ips/15 ips
■
EVENT REC
Set the recording rate, recording duration and the event
action mode when an event (site alarm, terminal alarm,
command alarm) occurs.
The following are available for "Recording Rate".
OFF/0.1 ips/0.2 ips/0.3 ips/0.5 ips/1 ips/2 ips/3 ips/
5 ips/10 ips/15 ips
The following are available for "Time" (recording dura-
tion).
1 s - 10 s (in 1 second intervals)/20 s/30 s/1 min -
10 min (in 1 minute intervals)/20 min/30 min/40 min/
50 min/ 60 min
MANUAL:
Recording will be performed while alarm sig-
nals (site alarm, terminal alarm, command alarm)
are being supplied.
CONTINUE:
Recording will not stop until the [ALARM
RESET] button is clicked.
Notes:
• When "MANUAL" is selected for "Time" (recording
duration), recording will be performed for at least 8
seconds at an event occurrence as long as the
alarm is not canceled.
• Pre-event recording will not be performed.
The following are available for the event action mode.
Refer to the Operating Instructions (PDF) for further
information about each event action mode.
ADM (Activity Detection Mode):
Performs recording,
preset function and writing an event log at an event
occurrence. Other event actions will not be per-
formed.
ALM (Alarm Mode):
Performs recording, preset func-
tion and writing an event log, supplying the alarm
output and sounding the buzzer according to the set-
tings for "Event Setup".
OFF:
Performs only recording of the event log. Other
event actions will not be performed.
■
EVENT SETUP
Perform the settings for the alarm output duration and
the buzzer sound duration at an event (site alarm, termi-
nal alarm or command alarm) occurrence.
The following are available for alarm output duration.
When OFF is selected, the alarm output will not be sup-
plied.
(s: second, min: minute)
1 s - 30 s (in 1 second intervals)/40 s/50 s/1 min/2 min/
3 min/4 min/5 min
EXT:
The alarm output will continue until the [ALARM
RESET] button is clicked.
OFF:
No alarm output is supplied.
REC:
The alarm output will be supplied during recording
is being performed.
The following are available for "Buzzer" (buzzer sound
duration).
When OFF is selected, a buzzer will not sound.
1 s - 30 s (in 1 second intervals)/40 s/50 s/1 min/2 min/
3 min/4 min/5 min
EXT:
The buzzer will continue until the [ALARM
RESET] button is clicked.
OFF:
The buzzer will not sound.
REC:
The buzzer will sound only during recording is
being performed.
■
Power ON Manual REC
Select ON or OFF to determine whether or not to start
recording when the power is turned on by the connected
external timer (or the switch).
ON:
Manual recording will start automatically after com-
pleting the system check.
OFF:
Manual recording will not start automatically after
completing the system check.