29
About the alarm action
• Start recording.
Recording will start at an event occurrence. Recording will be performed according to the settings such as
recording duration, recording rate, etc. that were configured on the setup menu. (Refer to the Setup Instructions
(PDF) for further information.)
Depending on the settings, it is possible to start recording images before an event occurs (Pre-event recording).
• Displays alarm message.
The pop-up window that notifies of an event occurrence will be displayed at an event occurrence.
• Blinks the alarm indicator.
The alarm indicator on the front panel of the unit will start blinking at an event occurrence.
• Sounds the buzzer.
The buzzer will start sounding for the set duration according to the settings configured on the setup menu. (Refer
to the Setup Instructions (PDF) for further information.)
• Move a camera to the preset position
The camera will move to the preset position registered in advance at an event occurrence. Refer to the operating
instructions of the connected camera for the descriptions of how to register the preset position.
• Notifies of an event occurrence by sending e-mails.
When an event occurs, this unit notifies of the event occurrence with the time and date of the event occurrence
by sending e-mails (alarm mails) to the registered addresses. It is also possible to attach an image to the alarm
mail.
Up to 4 addresses can be registered as recipients of the alarm mail.
To send the alarm mail at an event occurrence, it is required to perform the settings on the setup menu in
advance.
• Supplies a signal from the ALARM connector or the ALARM/CONTROL connector on the rear panel of
this unit (Alarm signal output).
It is possible to output signals from the ALARM connector on the rear panel of the unit and sound the buzzer
when an event occurs. The alarm output duration can be set on the setup menu. (Refer to the Setup Instructions
(PDF) for further information.)
• Record event log.
The event type and the occurrence time and date will be recorded when an event occurs.
• Transmits recorded images to an FTP server at an event occurrence
When an event occurs, recorded images will be continued transmitting to an FTP server automatically for the set
duration from the recording start time. To send the alarm image to an FTP server at an event occurrence, it is
required to perform the settings on the setup menu in advance. Refer to the Setup Instructions (PDF) for further
information.
• Notifies a PC of an alarm occurrence according to the Panasonic alarm protocol settings.
Select "ON" or "OFF" to determine whether or not to notify of an alarm occurrence (or error information) to a PC
according to the "Panasonic Alarm Protocol" of the setup menu ("Comm" – "Panasonic Alarm Protocol").
To receive a notification (or error information) and display the contents of the notification, the optional software
(WV-AS65) is necessary.