13
2
Rack mounting
Step 3
Place the provided rack mounting brackets (provided)
on both sides of the recorder and fix them with the
rack mounting bracket fixing screw (provided) (×6).
Secure them using the rack mounting bracket fixing screw
(provided) (×6).
Tightening torque: 0.88 N·m ~ 1.08 N·m (0.65 lbf·ft ~ 0.80 lbf·ft)
Rack mounting bracket fixing screws (provided)
Rack handle (provided)
Rack mounting brackets (provided)
Rack handle (provided)
Step 4
Install the recorder in the rack by using four rack
mounting screws.
Secure using the rack mounting screws (×4).
Tightening torque: 2.0 N·m ~ 2.4 N·m (1.48 lbf·ft ~ 1.78 lbf·ft)
Rack mounting screws (M5 x 12, locally procured)
Important:
• When installing the recorder in the rack, make a space
of 1U (44 mm {1-23/32 inches}) above and below the
recorder for ventilation.
• Keep the temperature in the rack below +45 °C {113 °F}.
• It is recommended to install cooling fans or equivalents to
keep the temperature in the rack below +30 °C {86 °F}.
• Do not block the ventilation holes or slots to prevent the
recorder from overheating.
• The recorder weighs over 10 k
g
{22.1 lbs}. Be careful
not to drop the recorder when installing it into a rack.
Dropping may cause damage, deformation of the
recorder, or injury.
Install the recorder in an EIA standard 19-inch rack (Depth:
550 mm or more).
Note:
• Use four M5 × 12 screws (locally procured) to install the
recorder in a rack.
• The illustration on this page is schematic. Details of the
shape are omitted.
Installation procedure
Step 1
Remove the five rubber feet from the bottom of the
recorder using a flathead screwdriver.
Use a screwdriver to remove the screws holding the rubber feet.
Remove rubber feet
Step 2
Attach the rack handles (provided) to the rack mount-
ing brackets (provided).
Fix them using the screws (provided) (×4) and the washers
(provided) (×4) for the rack handle.
Tightening torque: 2.0 N·m ~ 2.4 N·m (1.48 lbf·ft ~ 1.78 lbf·ft)
Washer (provided)
Screws for the rack handle (provided)
Rack mounting bracket (provided)
Washer (provided)
Rack handle (provided)
Note:
• The rack mounting bracket (provided) has two types of
fitting holes to adjust the protrusion of the front rack. Use
either of them depending on the installation conditions.
Standard fitting holes
Fitting holes for the front position (about 15 mm {19/32 inches})