83
• Is the LAN cable firmly connected to the network
port?
Confirm that the cord is firmly connected.
• When the PC in use does not meet the system
requirement, the image refresh interval may become
longer and the speed of fast playback may become
slow.
• The image refresh interval may become longer and
the speed of fast playback may become slow when
the amount of data to be transmitted or the load to be
processed by the recorder is large.
The image refresh is very
slow, or not be refreshed.
–
5
• Is the same IP address provided to other devices?
Refer to a system administrator for further informa-
tion.
• Is the valid IP address set?
Refer to a system administrator for further informa-
tion.
• Is the connection indicator of the 10BASE-T/-
100BASE-TX port lit?
When it is not lit, connection to a LAN is not estab-
lished or a network is not working correctly.
Confirm that the connection indicator of the 10BASE-
T/100BASE-TX port is lit. Refer to a system adminis-
trator if it is not lit.
• Are there contradictions between the address and the
network subnet to be accessed?
When this unit and the client PC are in the same sub-
net, are the IP addresses of this unit and the client PC
set in same subnet?
When accessing this unit in the same subnet, entering
the address of this unit in the "Don’t Use Proxy For
These Addresses" box is recommended.
–
Cannot establish the con-
nection
Cannot configure the set-
tings
Cannot operate the recorder
Refer to the
installation
guide.
63
–
–
Cause/solution
Reference
pages
Symptom
• It may be caused by heavy network traffic or narrow
bandwidth.
–