3-135
Chapter 3 Troubleshooting
3. 4. 4. 3 DC120 Failure Counter
Description
Displays the No. of Occurrences of each failure from the time of reset on completion
of the previous servicing up to now.
• The following screen appears on the Failure Counter Screen. (Default is displayed in the order
of No. of Occurrences.)
A. Display in the order of No. of Occurrences.
B. Display in the order of Chain Link No.
C. Specify the Chain No.
A. Display in the order of No. of Occurrences.
(Displays the list starting with a failure having
occurred most frequently.)
Procedure
1. Select the "Counter" tab on the Service Mode screen.
2. Select [
DC120
] on the Counter screen.
3. Select [Display in the order of No. of Occurrences].
4. Failure Counter Screen: Displays in the order of No. of Occurrences.
• Based on the data obtained from the Main Processor, the PSW displays the data in the
order of No. of fail
ure
occurrences. If the No. of occurrences is the same, the PSW
displays the data in the order of Chain Link No.
• Displays failures from the last exit from the Service Mode with "Complete the
operation" until now.
• The No. of Occurrences is the item to be reset at the time of exit from the Service
Mode by use of "Complete the operation".
5. Select [Close] to return to the Counter screen after checking of the Display in the order of
No. of Occurrences has completed.
B. Display in the order of Chain Link No. (Displays the list in the order of Chain Link No.)
Procedure
1. Select the "Counter" tab on the Service Mode screen.
2. Select [
DC120
] on the Counter screen.
3. Select [Display in the order of Chain Link No.].
4. The
Failure
Counter: Display in the order of Chain Link No. screen is displayed.
• Based on the data obtained from the Main Processor, the PSW displays failures in the
order of Chain Link No.
• Displays failures from the last exit from the Service Mode with "Complete the
operation" until now.
• The No. of Occurrences is the item to be reset at the time of exit from the Service
Mode by use of "Complete the operation".
5. Select [Close] to return to the Counter screen after checking of the display in order of Chain
Link has completed.
C. Specify the Chain No.
(Displays Specify the Chain No.)
Procedure
1. Select the "Counter" tab on the Service Mode screen.
2. Select [
DC120
] on the Counter screen.
3. Select [Specify the Chain No.].
4. The Enter the Chain No. screen is displayed.
5. Enter the Chain No. using the keyboard and select [OK].
6. The Failure Counter: Specify the Chain No. screen is displayed.
• Based on the data obtained from the Main Processor, the PSW displays the data only
on the Failures in the order of Chain Link No.
• Displays failures from the last exit from the Service Mode with "Complete the
operation" until now.
• The No. of Occurrences is the item to be reset at the time of exit from the Service
Mode by use of "Complete the operation".
7. Select [Close] to return to the Counter screen after checking of the display in order of Chain
Link has completed.
Does not count fails detected in the Service Mode. Does not count the interlock open
detected while the Main Processor is stopped.
As No. of Occurrences and troubles are not managed, these items and P1, P2 and P3 are
not displayed.
The data is obtained when opening the screen or entering the Service Mode (If you
double click [Service Mode] with the [Z] key pressed.)
The data is obtained when opening the screen or entering the Service Mode (If you
double click [Service Mode] with the [Z] key pressed.)
The data is obtained when opening the screen or entering the Service Mode (If you
double click [Service Mode] with the [Z] key pressed.)
Summary of Contents for Workio DP-C401
Page 4: ...This page is intentionally left blank ...
Page 5: ...Chapter 1 General ...
Page 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Page 23: ...1 17 Chapter 1 General ...
Page 24: ...Chapter 2 Maintenance ...
Page 63: ...Chapter 3 Troubleshooting ...
Page 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Page 445: ...Chapter 4 Parts List ...
Page 548: ......