3-147
Chapter 3 Troubleshooting
3. 4. 4. 14 DC956 Belt Edge Learn Mode (Sub System)
Function To set the machine in the Edge Learn mode at factory shipment or replacement of Belt
parts (IBT Belt, Edge sensor), creates the Edge Profile Table (table used to control the Belt Walk).
Reference
Execution Time: 100 sec at maximum (13 revolutions of the Belt)
Procedure
1. Select the [Sub System] tab on the Service Mode screen.
2. Select [
DC956
] on the Sub System screen.
3. The "Belt Edge Learn" screen is displayed.
4. Select [Execute].
5. Select [Close] to return to the Sub System screen.
Always perform this diag before executing DC685 and complete it successfully.