3-228
Chapter 3 Troubleshooting
[PSW Display]: Full Stack Paper Sensing Condition
[Initial Value]: 4
[Setup Range]: 1~12 (1 Count: 5 sec)
[Description]: Full Stack Detection Condition (5~60 sec), Defalut: 20
13. 742-019
[NVM Name]: Full Stack Paper Cancel Condition
[PSW Display]: Full Stack Paper Cancel Condition
[Initial Value]: 1
[Setup Range]: 1~30 (1 Count: 1 sec)
[Description]: Full Stack Cancel Condition (1~30 sec), Defalut: 1sec
14. 742-020
[NVM Name]: Feed Start Timing (MSI)
[PSW Display]: Feed Start Timing (MSI)
[Initial Value]: 41
[Setup Range]: 0~82 (1 Count: 2.4462 ms)
[Description]: Feed Start Timing Adjustment from Pitch (P Speed) (512~712 ms)
15. 742-021
[NVM Name]: Feed Start Timing (MSI) (MF)
[PSW Display]: Feed Start Timing (MSI) (MF)
[Initial Value]: 150
[Setup Range]: 0~300 (1 Count: 1.32236 ms)
[Description]:
Feed Start Timing Adjustment from Pitch (Double Speed) (650~850 ms)
16. 742-022
[NVM Name]: Feed Motor Off Timing
[PSW Display]: Feed Motor Off Timing
[Initial Value]: 10
[Setup Range]: 0~35 (1 Count: 10 ms)
[Description]: Feed Motor Off Timing Adjustment from T/A Nip
17. 742-023
[NVM Name]: Regi Clutch Off Timing
[PSW Display]: Regi Clutch Off Timing
[Initial Value]: 41
[Setup Range]: 0~81 (1 Count: 2.4462 ms)
[Description]:
Adjusts the time between the paper rear edge has passes the Regi Sensor and the
Regi Clutch Turns Off (P Speed) (90~290 ms).
18. 742-024
[NVM Name]: Regi Clutch Off Timing (MF)
[PSW Display]: Regi Clutch Off Timing (MF)
[Initial Value]: 76
[Setup Range]: 0~152 (1 Count: 1.31136 ms)
[Description]:
Adjusts the time between the paper rear edge has passes the Regi Sensor and the
Regi Clutch Turns Off (Double Speed)
19. 742-025
[NVM Name]: ADJUST SIDE REGI (ALL)
[PSW Display]: ADJUST SIDE REGI (ALL)
[Initial Value]: 25
[Setup Range]: 0~50 (1 Count: 0.211 mm)
[Description]: Side Regi Adjustment (ALL, Offset value)
20. 742-026
[NVM Name]: ADJUST SIDE REGI (MSI)
[PSW Display]: ADJUST SIDE REGI (MSI)
[Initial Value]: 22
[Setup Range]: 0~50 (1 Count: 0.211 mm)
[Description]: Side Regi Adjustment (MSI)
21. 742-027
[NVM Name]: ADJUST SIDE REGI (Dup)
[PSW Display]: ADJUST SIDE REGI (Dup)
[Initial Value]: 18
[Setup Range]: 0~50 (1 Count: 0.211 mm)
[Description]: Side Regi Adjustment (Dup)
22. 742-028
[NVM Name]: ADJUST LEAD REGI (ALL)
[PSW Display]: ADJUST LEAD REGI (ALL)
[Initial Value]: 20
[Setup Range]: 0~40 (1 Count: 0.2544 mm)
[Description]: Lead Regi Adjustment (ALL, Offset value)
23. 742-029
[NVM Name]: ADJUST LEAD REGI (Tray)
[PSW Display]: ADJUST LEAD REGI (Tray)
[Initial Value]: 6
[Setup Range]: 0~40 (1 Count: 0.2544 mm)
Summary of Contents for Workio DP-C401
Page 4: ...This page is intentionally left blank ...
Page 5: ...Chapter 1 General ...
Page 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Page 23: ...1 17 Chapter 1 General ...
Page 24: ...Chapter 2 Maintenance ...
Page 63: ...Chapter 3 Troubleshooting ...
Page 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Page 445: ...Chapter 4 Parts List ...
Page 548: ......