3-229
Chapter 3 Troubleshooting
[Description]: Lead Regi Adjustment (P Speed) from Tray
24. 742-030
[NVM Name]: ADJUST LEAD REGI (Tray) (MF)
[PSW Display]: ADJUST LEAD REGI (Tray) (MF)
[Initial Value]: 21
[Setup Range]: 0~40 (1 Count: 0.2544 mm)
[Description]: Lead Regi Adjustment (Double Speed) from Tray
25. 742-031
[NVM Name]: ADJUST LEAD REGI (MSI) (22P Standard Paper)
[PSW Display]: ADJUST LEAD REGI (MSI) (Standard Paper)
[Initial Value]: 10
[Setup Range]: 0~40 (1 Count: 0.2544 mm)
[Description]: Lead Regi Adjustment (P Speed) Standard Paper from MSI (22P exclu-
sive)
26. 742-032
[NVM Name]: ADJUST LEAD REGI (MSI) (MF Standard Paper)
[PSW Display]: ADJUST LEAD REGI (MSI) (Standard Paper) (MF)
[Initial Value]: 21
[Setup Range]: 0~40 (1 Count: 0.2544 mm)
[Description]: Lead Regi Adjustment (Double Speed) Standard Paper from MSI
27. 742-033
[NVM Name]: ADJUST LEAD REGI (MSI) (MF Heavy1)
[PSW Display]: ADJUST LEAD REGI (MSI) (MF) (Heavy1)
[Initial Value]: 20
[Setup Range]: 0~40 (1 Count: 0.2544 mm)
[Description]: Lead Regi Adjustment (P Speed) Heavy Weight Paper 1 from MSI (MF
exclusive)
28. 742-034
[NVM Name]: ADJUST LEAD REGI (MSI) (MF Heavy 2)
[PSW Display]: ADJUST LEAD REGI (MSI) (MF) (Heavy2)
[Initial Value]: 7
[Setup Range]: 0~40 (1 Count: 0.2544 mm)
[Description]: Lead Regi Adjustment (Half Speed) Heavy Weight Paper 2 from MSI
(MF exclusive)
29. 742-035
[NVM Name]: ADJUST LEAD REGI (MSI 22P Heavy Weight Paper 1)
[PSW Display]: ADJUST LEAD REGI (MSI) (Heavy Paper1)
[Initial Value]: 7
[Setup Range]: 0~40 (1 Count: 0.2544 mm)
[Description]: Lead Regi Adjustment (Half Speed) Heavy Weight Paper 1 from MSI
(22P exclusive)
30. 742-036
[NVM Name]: ADJUST LEAD REGI (MSI 22P Heavy Weight Paper 2)
[PSW Display]: ADJUST LEAD REGI (MSI) (Heavy Paper2)
[Initial Value]: 7
[Setup Range]: 0~40 (1 Count: 0.2544 mm)
[Description]: Lead Regi Adjustment (Half Speed) Heavy Weight Paper 2 from MSI
(22P exclusive)
31. 742-037
[NVM Name]: ADJUST READ REGI (DUP)
[PSW Display]: ADJUST LEAD REGI (Dup)
[Initial Value]: 21
[Setup Range]: 0~40 (1 Count: 0.2544 mm)
[Description]: Lead Regi Adjustment (P Speed) (Side2)
32. 742-038
[NVM Name]: ADJUST LEAD REGI (DUP) (MF)
[PSW Display]: ADJUST LEAD REGI (Dup) (MF)
[Initial Value]: 21
[Setup Range]: 0~40 (1 Count: 0.2544 mm)
[Description]: Lead Regi Adjustment (Double Speed) (Side2)
33. 742-039
[NVM Name]: JamBypass
[PSW Display]: Jam Bypass
[Initial Value]: 0
[Setup Range]: 0~255
[Description]: 0: Normal Mode 255: JamPypass
34. 742-046
[NVM Name]: FaceUpTray Availability
[PSW Display]: Face Up Tray Condition
[Initial Value]: 0
[Setup Range]: 0~1
[Description]:
FaceUpTray
0: No
Summary of Contents for Workio DP-C401
Page 4: ...This page is intentionally left blank ...
Page 5: ...Chapter 1 General ...
Page 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Page 23: ...1 17 Chapter 1 General ...
Page 24: ...Chapter 2 Maintenance ...
Page 63: ...Chapter 3 Troubleshooting ...
Page 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Page 445: ...Chapter 4 Parts List ...
Page 548: ......