3-368
Chapter 3 Troubleshooting
2. Select the button to be initialized and select [Execute].
3. The following message will appear. Select [Yes (Initialize)].
4. The message indicating the completion will appear.
5. Select the [Confirm] button.
This completes the initialization.
3. 6. 1. 2 Hard Disk Initialization (UI: DC305)
Initialization Procedure
1. Select [Hard Disk Initialization] on the Diagnostics screen in the CE mode.
The Partition A button will appear.
2. Select the Partition A button and select [Execute].
3. The following message will appear. Select [Yes (Initialize)].
4. The message indicating the completion will appear.
5. Select the [Confirm] button.
This completes the initialization of the Partition A.
3. 6. 1. 3 NVM Read/Write (UI:DC131)
Procedure
1. Select [NVM Read/Write] on the Diagnostics screen in the CE mode.
2. Input the Chain-Link No. in six digits and press the [Confirm/Change] button.
3. The current setting value will be displayed. The text box for inputting the changed value
will be displayed.
4. Input the number to be changed to. The number will be input in the changed value column.
5. Select [Confirm].
6. The input number will be displayed in the current number column.
This completes the NVM Read/Write operation.
Sys-System
- 700-
006,065?070,088.116,122,127,128,147,164?166,174
,176?181,197,208
- 701-912,917,924,929
- 720-002
- 730-001?006
- 770-124,203
- 780-065?068
- 785-008,009
- 790-003,004,099
- 801-104,204,304,404,504,604,704,804,904
- 802-004,104,204,304,404,504,604,704,804,904
- 803-004
- 810-002?019,038?127
- 820-003,007?009,017?019,024,026,027,029
- 823-001?005,008?011,030?047
- 830-001?004,084,085
- 850-001?004,007,009?012,015
- 860-009,013,020,025,031,032
Sys-User
Initialization Items for User
The items that can be changed by a User in the
following Chain No. will be initialized.
Chain No.: 700, 780, 785, 790, 800, 801, 802, 803,
804, 805, 806, 810, 820, 823, 830, 840
All
All of the above NVM will be initialized.
Only the hard disk in the partition A is initialized in the UI-Diag. Use PC-Diag DC355
when the other partitions are to be initialized.
Button Names
Chain No. to be initialized at execution
Partition No.
Default size
(Gbytes)
Use
Partition 1 (A)
2
For copying
Partition 2 (B)
2
For printing
Partition 3 (C)
1.5
Scan, Mail Box, Secure Print
Partition 4 (D)
5
Spool Cont. control information, log
Partition 5 (E)
2
PDL, Others
Partition 6 (F)
0.5
Fonts, Form/Logo, SMB folder (config.txt, driver) Job
template
All NVM can be set with the NVM Read/Write on the UI. However, be careful not to
input Chain-Link No. wrongly because the names of the NVM are not displayed on the
UI. (For the NVM items, refer to each Chain-Link No. in 3.5.6 Service Data.)
E.g.) The machine does not accept "700-6" as a abbreviation of "700-006". Therefore,
input all 6 digits even though the first number is "0".
Summary of Contents for Workio DP-C401
Page 4: ...This page is intentionally left blank ...
Page 5: ...Chapter 1 General ...
Page 22: ...1 16 Chapter 1 General 1 3 Type of Paper ...
Page 23: ...1 17 Chapter 1 General ...
Page 24: ...Chapter 2 Maintenance ...
Page 63: ...Chapter 3 Troubleshooting ...
Page 118: ...3 44 Chapter 3 Troubleshooting I F PWB PL9 1 MCU PWB PL13 1 ...
Page 445: ...Chapter 4 Parts List ...
Page 548: ......