Wiring
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
49
<Using NPN output>
Main circuit
Main circuit
0.1μF
0.1μF
0.1μF
470Ω
470Ω
470Ω
Emitter
Receiver
Internal circuit
Internal circuit
Users’ circuit
Users’ circuit
(Brown) +V
(Brown) +V
(Pale purple) Interlock setting input
(Pink) Test / Reset input
(Red) Auxiliary output
(Pale blue) Output polarity setting / Lockout release input
(Pale blue) Output polarity setting /
Lockout release input
(Blue) 0V
(Blue) 0V
(Orange) Synchroni
(Pale purple) External device monitor input
(Black) Control output 1 (OSSD 1)
(White) Control output 2 (OSSD 2)
(Orange) Synchroni
(Orange / Black) Synchronization -
(Orange / Black) Synchronization -
*S1
*S1
Load
K1
K2
+ 24V DC
+20
-30
%
−
K1 K2
6.8kΩ
6.8kΩ
6.8kΩ
6.8kΩ
6.8kΩ
6.8kΩ
*S1
Switch S1
●
Test / Reset input
Manual reset …0 to +2.5V (source current 5mA or less): Emission halt, Open: Emission
Auto reset …0 to +2.5V (source current 5mA or less): Emission, Open: Emission halt
●
Interlock setting input, External device monitor input
0 to +2.5V (source current 5mA or less): Valid, Open: Invalid
<Reference>
K1, K2: External device (forcible guide relay or magnetic conductor)
Summary of Contents for WUME-SF4D-4
Page 2: ... Panasonic Industrial Devices SUNX Co Ltd 2017 2 MEMO ...
Page 126: ...Functions Panasonic Industrial Devices SUNX Co Ltd 2017 126 MEMO ...
Page 130: ...Maintenance Panasonic Industrial Devices SUNX Co Ltd 2017 130 MEMO ...
Page 140: ...Troubleshooting Panasonic Industrial Devices SUNX Co Ltd 2017 140 MEMO ...
Page 174: ... Panasonic Industrial Devices SUNX Co Ltd 2017 174 MEMO ...