Adjustment
© Panasonic Industrial Devices SUNX Co., Ltd. 2017
86
●
Receiver indicator operation 3
<Conditions: Line synchronization, Test input function invalid, Interlock function valid>
Receiver
Light blocked state
Light received state (all beam channels)
Top end beam channel
Interlock
state
Unstable
light recep-
tion state
Stable light reception state
Light
blocked
Light
received
Light
blocked
Light
received
Bottom end beam
Received light intensity
Light
blocked
Light
blocked
Light
received
Light
received
Other beam channels
Level 3
Level 1
Level 1
Level 2
Level 3
Light received
/ Light blocked
Light received
/ Light blocked
Light received
/ Light blocked
Light
blocked
Interlock state
Interlock released state
Control output
(OSSD 1 / 2)
OFF
OFF
OFF
OFF
OFF
ON
ON
ON
ON
Upper application
indicator (Note 1)
Turns OFF
Lights
red
Turns OFF
Lights
red
Lights
red
Lights
blue
Lights
blue
Lights
blue
Lights
blue
Lower application
indicator (Note 1)
Turns OFF Turns OFF
Lights
red
Lights
red
Lights
red
Lights
blue
Lights
blue
Lights
blue
Lights
blue
Stable light re-
ception indicator
Turns OFF Turns OFF Turns OFF Turns OFF
Lights
green
Lights
orange
Lights
green
Lights
green
Lights
green
Digital indicator
Turns OFF Turns OFF Turns OFF Turns OFF
Green 3
lights
Green 1
lights
Green 1
lights
Green 2
lights
Green 3
lights
Frequency
indicator
Turns OFF Turns OFF Turns OFF Turns OFF Turns OFF Turns OFF Turns OFF Turns OFF Turns OFF
Function setting
indicator (Note 2)
Turns OFF Turns OFF Turns OFF Turns OFF Turns OFF Turns OFF Turns OFF Turns OFF Turns OFF
Interlock
indicator
Lights
yellow
Lights
yellow
Lights
yellow
Lights
yellow
Lights
yellow
Turns OFF Turns OFF Turns OFF Turns OFF
OSSD indicator
Lights
red
Lights
red
Lights
red
Lights
red
Lights
red
Lights
green
Lights
green
Lights
green
Lights
green
Notes: 1) The states of the upper application indicator and lower application indicator can also be checked from
the side of the device.
2) The function setting indicator (yellow / orange) lights yellow when the blanking function or parallel con-
nection is used, and blinks orange when the communication module
SF4D-TM1
(option) is connected.
Summary of Contents for WUME-SF4D-4
Page 2: ... Panasonic Industrial Devices SUNX Co Ltd 2017 2 MEMO ...
Page 126: ...Functions Panasonic Industrial Devices SUNX Co Ltd 2017 126 MEMO ...
Page 130: ...Maintenance Panasonic Industrial Devices SUNX Co Ltd 2017 130 MEMO ...
Page 140: ...Troubleshooting Panasonic Industrial Devices SUNX Co Ltd 2017 140 MEMO ...
Page 174: ... Panasonic Industrial Devices SUNX Co Ltd 2017 174 MEMO ...